Language:
English
繁體中文
Help
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Development of a carbon fiber reinforced polymer prestressing system for structural applications.
Record Type:
Language materials, manuscript : Monograph/item
Title/Author:
Development of a carbon fiber reinforced polymer prestressing system for structural applications./
Author:
Burningham, Clayton A.
Description:
1 online resource (111 pages)
Notes:
Source: Dissertations Abstracts International, Volume: 73-06, Section: B.
Contained By:
Dissertations Abstracts International73-06B.
Subject:
Civil engineering. -
Online resource:
click for full text (PQDT)
ISBN:
9781267027153
Development of a carbon fiber reinforced polymer prestressing system for structural applications.
Burningham, Clayton A.
Development of a carbon fiber reinforced polymer prestressing system for structural applications.
- 1 online resource (111 pages)
Source: Dissertations Abstracts International, Volume: 73-06, Section: B.
Thesis (Ph.D.)--The University of Utah, 2011.
Includes bibliographical references
Prestressed concrete has been a significant contributor to the success of modern civil engineering projects because it allows longer spans and lighter members to be constructed. Despite the usefulness of prestressed concrete, a major disadvantage is the susceptibility of steel prestressing tendons to corrosion. Corrosion can be accelerated by vehicular impact damage which removes concrete cover, exposing the tendons to the elements. If damaged members can be repaired with fiber reinforced polymer (FRP) composites, total replacement of the structure can be avoided. FRP composites are excellent candidates for use in prestressing because of their light weight, superior resistance to corrosion, and comparable strength to steel. Post-tensioned external FRP tendons can be implemented to restore capacity lost through corrosion or damage or meet increased load requirements; however, there are three obstacles that have hindered wide implementation of external FRP post-tensioning in rehabilitation and retrofit applications. The following obstacles inhibit implementation: the lack of a suitable anchorage device to maintain the post-tensioning force in the FRP tendons, the lack of an innovative stressing device that reduces the requirement for a significant amount of free space behind the post-tensioned member, and the lack of design equations detailing the use of FRP tendons for field applications. This research involves overcoming the three aforementioned obstacles. The first part of this research is concerned with the development of a unibody clamp anchor that controls slip and stress concentrations in post-tensioned carbon fiber reinforced polymer (CFRP) rods. Additionally, finite element modeling was employed to conduct a relative comparison of the anchor performance across four different design generations. A second objective of the research was to design and implement a simple mechanical stressing device and the unibody clamp anchors to damaged reinforced concrete beams controlled by shear and damaged prestressed concrete beams controlled by flexure. The final objective considered in the research was an evaluation of design equations from the literature. In short, this research as a whole demonstrates the ability to utilize external post-tensioned CFRP rods for structural repair applications, and forecasts their potential for more widespread use.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2024
Mode of access: World Wide Web
ISBN: 9781267027153Subjects--Topical Terms:
561339
Civil engineering.
Subjects--Index Terms:
AnchorIndex Terms--Genre/Form:
554714
Electronic books.
Development of a carbon fiber reinforced polymer prestressing system for structural applications.
LDR
:03863ntm a22004097 4500
001
1152059
005
20241125080225.5
006
m o d
007
cr mn ---uuuuu
008
250605s2011 xx obm 000 0 eng d
020
$a
9781267027153
035
$a
(MiAaPQ)AAI3482167
035
$a
(MiAaPQ)utah:10916
035
$a
AAI3482167
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Burningham, Clayton A.
$3
1478941
245
1 0
$a
Development of a carbon fiber reinforced polymer prestressing system for structural applications.
264
0
$c
2011
300
$a
1 online resource (111 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 73-06, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Pantelides, Chris P.
502
$a
Thesis (Ph.D.)--The University of Utah, 2011.
504
$a
Includes bibliographical references
520
$a
Prestressed concrete has been a significant contributor to the success of modern civil engineering projects because it allows longer spans and lighter members to be constructed. Despite the usefulness of prestressed concrete, a major disadvantage is the susceptibility of steel prestressing tendons to corrosion. Corrosion can be accelerated by vehicular impact damage which removes concrete cover, exposing the tendons to the elements. If damaged members can be repaired with fiber reinforced polymer (FRP) composites, total replacement of the structure can be avoided. FRP composites are excellent candidates for use in prestressing because of their light weight, superior resistance to corrosion, and comparable strength to steel. Post-tensioned external FRP tendons can be implemented to restore capacity lost through corrosion or damage or meet increased load requirements; however, there are three obstacles that have hindered wide implementation of external FRP post-tensioning in rehabilitation and retrofit applications. The following obstacles inhibit implementation: the lack of a suitable anchorage device to maintain the post-tensioning force in the FRP tendons, the lack of an innovative stressing device that reduces the requirement for a significant amount of free space behind the post-tensioned member, and the lack of design equations detailing the use of FRP tendons for field applications. This research involves overcoming the three aforementioned obstacles. The first part of this research is concerned with the development of a unibody clamp anchor that controls slip and stress concentrations in post-tensioned carbon fiber reinforced polymer (CFRP) rods. Additionally, finite element modeling was employed to conduct a relative comparison of the anchor performance across four different design generations. A second objective of the research was to design and implement a simple mechanical stressing device and the unibody clamp anchors to damaged reinforced concrete beams controlled by shear and damaged prestressed concrete beams controlled by flexure. The final objective considered in the research was an evaluation of design equations from the literature. In short, this research as a whole demonstrates the ability to utilize external post-tensioned CFRP rods for structural repair applications, and forecasts their potential for more widespread use.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2024
538
$a
Mode of access: World Wide Web
650
4
$a
Civil engineering.
$3
561339
653
$a
Anchor
653
$a
Carbon fiber reinforced polymer
653
$a
Composites
653
$a
Post-tensioning
653
$a
Reinforced polymer prestressing
653
$a
Repair
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0543
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
The University of Utah.
$b
Civil and Environmental Engineering.
$3
1184728
773
0
$t
Dissertations Abstracts International
$g
73-06B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3482167
$z
click for full text (PQDT)
based on 0 review(s)
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login
Please sign in
User name
Password
Remember me on this computer
Cancel
Forgot your password?