語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance./
作者:
Boucher, Michael Claude.
面頁冊數:
1 online resource (263 pages)
附註:
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
Contained By:
Dissertations Abstracts International85-07B.
標題:
Physical chemistry. -
電子資源:
click for full text (PQDT)
ISBN:
9798381412406
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
Boucher, Michael Claude.
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
- 1 online resource (263 pages)
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
Thesis (Ph.D.)--Cornell University, 2023.
Includes bibliographical references
The ability to use magnetic resonance to detect and image free radical spin labels will enable structural determination from individual spin-labeled biomolecules and biomolecular complexes. In 2004, single electron magnetic resonance detection was first demonstrated using Magnetic Resonance Force Microscopy (MRFM), a technique in which sample magnetization is detected as a force, or force gradient, on a high-sensitivity cantilever. However, this 2004 measurement required a highly specialized sample and long acquisition times. More recently, a force-gradient detection scheme, Cantilever Enabled Readout of Magnetization Inversion Transients (CERMIT), more applicable to the short coherence times of spin labels, has been developed. In CERMIT the cantilever is self-oscillated, and the signal is the cantilever frequency shift. In this dissertation, we discuss the development of a new approach to sample preparation for CERMIT experiments. While the primary limitation to MRFM sensitivity is surface noise, coating the polymer sample with metal decreases sample frequency noise by a significant factor. We use MRFM and inductively detected measurements to show that the deposition of this metallic overlayer damages or inactivates nitroxide spin labels at the top of the sample. Our new approach to sample preparation deposits the gold metal layer onto a sacrificial polymer instead of directly onto the sensitive radicals. We perform MRFM measurements on this new "laminate" sample using a cantilever with a nanoscale tip and show a 20-fold increase in spin signal. While this increase in signal size is highly significant, it is still an order of magnitude smaller than predicted by simulations. In this dissertation we will also investigate possible reasons for the reduced signal size in this experiment and previous measurements that were performed with nanoscale magnetic tips. We explore the effects of poor tip field gradients from magnet damage, of spin-lattice relaxation due to tip magnetization fluctuations, and incomplete saturation of sample spins due to the motion of the magnetic tip. We use the Bloch equations to derive an expression for the saturation and incorporate this new expression into the simulation code. We show that the results are significantly better than previous simulations at matching experimental signals from both micron-scale and nanoscale magnetic tips.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2024
Mode of access: World Wide Web
ISBN: 9798381412406Subjects--Topical Terms:
1148725
Physical chemistry.
Subjects--Index Terms:
Electron spin resonanceIndex Terms--Genre/Form:
554714
Electronic books.
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
LDR
:03850ntm a22004217 4500
001
1151826
005
20241118135834.5
006
m o d
007
cr mn ---uuuuu
008
250605s2023 xx obm 000 0 eng d
020
$a
9798381412406
035
$a
(MiAaPQ)AAI30527698
035
$a
AAI30527698
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Boucher, Michael Claude.
$3
1478659
245
1 0
$a
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
264
0
$c
2023
300
$a
1 online resource (263 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
500
$a
Advisor: Marohn, John.
502
$a
Thesis (Ph.D.)--Cornell University, 2023.
504
$a
Includes bibliographical references
520
$a
The ability to use magnetic resonance to detect and image free radical spin labels will enable structural determination from individual spin-labeled biomolecules and biomolecular complexes. In 2004, single electron magnetic resonance detection was first demonstrated using Magnetic Resonance Force Microscopy (MRFM), a technique in which sample magnetization is detected as a force, or force gradient, on a high-sensitivity cantilever. However, this 2004 measurement required a highly specialized sample and long acquisition times. More recently, a force-gradient detection scheme, Cantilever Enabled Readout of Magnetization Inversion Transients (CERMIT), more applicable to the short coherence times of spin labels, has been developed. In CERMIT the cantilever is self-oscillated, and the signal is the cantilever frequency shift. In this dissertation, we discuss the development of a new approach to sample preparation for CERMIT experiments. While the primary limitation to MRFM sensitivity is surface noise, coating the polymer sample with metal decreases sample frequency noise by a significant factor. We use MRFM and inductively detected measurements to show that the deposition of this metallic overlayer damages or inactivates nitroxide spin labels at the top of the sample. Our new approach to sample preparation deposits the gold metal layer onto a sacrificial polymer instead of directly onto the sensitive radicals. We perform MRFM measurements on this new "laminate" sample using a cantilever with a nanoscale tip and show a 20-fold increase in spin signal. While this increase in signal size is highly significant, it is still an order of magnitude smaller than predicted by simulations. In this dissertation we will also investigate possible reasons for the reduced signal size in this experiment and previous measurements that were performed with nanoscale magnetic tips. We explore the effects of poor tip field gradients from magnet damage, of spin-lattice relaxation due to tip magnetization fluctuations, and incomplete saturation of sample spins due to the motion of the magnetic tip. We use the Bloch equations to derive an expression for the saturation and incorporate this new expression into the simulation code. We show that the results are significantly better than previous simulations at matching experimental signals from both micron-scale and nanoscale magnetic tips.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2024
538
$a
Mode of access: World Wide Web
650
4
$a
Physical chemistry.
$3
1148725
650
4
$a
Materials science.
$3
557839
650
4
$a
Electromagnetics.
$3
1178899
650
4
$a
Nanoscience.
$3
632473
653
$a
Electron spin resonance
653
$a
Magnetic resonance force microscopy
653
$a
Magnetometry
653
$a
Nanofabrication
653
$a
Spin label
653
$a
Surface-induced dissipation
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0494
690
$a
0794
690
$a
0565
690
$a
0607
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
Cornell University.
$b
Chemistry and Chemical Biology.
$3
1190331
773
0
$t
Dissertations Abstracts International
$g
85-07B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30527698
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入
第一次登入時,112年前入學、到職者,密碼請使用身分證號登入;112年後入學、到職者,密碼請使用身分證號"後六碼"登入,請注意帳號密碼有區分大小寫!
帳號(學號)
密碼
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)