語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Orthodontic Treatment Using Advanced Engineering Technologies
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Orthodontic Treatment Using Advanced Engineering Technologies/ Amin Akbari.
作者:
Akbari, Amin,
面頁冊數:
1 electronic resource (121 pages)
附註:
Source: Dissertations Abstracts International, Volume: 87-04, Section: B.
Contained By:
Dissertations Abstracts International87-04B.
標題:
Dentistry. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32264807
ISBN:
9798291540183
Orthodontic Treatment Using Advanced Engineering Technologies
Akbari, Amin,
Orthodontic Treatment Using Advanced Engineering Technologies
[electronic resource] /Amin Akbari. - 1 electronic resource (121 pages)
Source: Dissertations Abstracts International, Volume: 87-04, Section: B.
Orthodontic treatment aims to correct dental misalignments; however, extended treatment duration and unpredictable force application remain significant clinical challenges. This dissertation presents two integrated engineering solutions to address these limitations: (1) acceleration of orthodontic tooth movement (OTM) through controlled vibrational force (VF), and (2) development of an experimental methodology for validating and optimizing clear aligner therapy (CAT) through force quantification and attachment design analysis. A scientific framework was established for accelerated OTM using intermittent vibrational force (IVF). Animal model experiments systematically evaluated the dose-response relationship of IVF parameters, including peak load, frequency, and application interval. An effective regimen (5 cN at 100 Hz, applied every four days or less) resulted in 63 to 76 percent greater tooth displacement compared to conventional orthodontic force (OF) alone. Micro-CT analysis revealed distinct bone remodeling patterns, with VF alone producing anabolic effects and combined OF and VF leading to synergistic changes in bone mineral density (BMD). Finite element modeling showed a correlation between von Mises stress distributions and BMD changes, supporting potential scalability to larger models and human application. To assess mechanical aspects of CAT, an orthodontic force tester (OFT) was developed. Quantitative analysis demonstrated that attachment geometry and placement significantly affect force systems. Fabrication-related issues such as trimming-induced variability (up to 36 percent deviation in moment) and material relaxation (22.9 percent force decay per cycle) were also identified, highlighting the importance of standardizing aligner production. These findings offer biologically and mechanically informed strategies to improve treatment efficiency and clinical predictability.
English
ISBN: 9798291540183Subjects--Topical Terms:
674038
Dentistry.
Subjects--Index Terms:
Orthodontic treatment
Orthodontic Treatment Using Advanced Engineering Technologies
LDR
:03253nam a22003733i 4500
001
1172950
005
20260622113228.5
006
m o d
007
cr|nu||||||||
008
260803s2025 miu||||||m |||||||eng d
020
$a
9798291540183
035
$a
(MiAaPQD)AAI32264807
035
$a
(MiAaPQD)Purdue29650124
035
$a
AAI32264807
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Akbari, Amin,
$e
author.
$3
1503600
245
1 0
$a
Orthodontic Treatment Using Advanced Engineering Technologies
$c
Amin Akbari.
$h
[electronic resource] /
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2025
300
$a
1 electronic resource (121 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 87-04, Section: B.
500
$a
Advisors: Chen, Jie Committee members: Turkkahraman, Hakan; Wagner, Diane; Yu, Huidan.
502
$b
Ph.D.
$c
Purdue University
$d
2025.
520
#
$a
Orthodontic treatment aims to correct dental misalignments; however, extended treatment duration and unpredictable force application remain significant clinical challenges. This dissertation presents two integrated engineering solutions to address these limitations: (1) acceleration of orthodontic tooth movement (OTM) through controlled vibrational force (VF), and (2) development of an experimental methodology for validating and optimizing clear aligner therapy (CAT) through force quantification and attachment design analysis. A scientific framework was established for accelerated OTM using intermittent vibrational force (IVF). Animal model experiments systematically evaluated the dose-response relationship of IVF parameters, including peak load, frequency, and application interval. An effective regimen (5 cN at 100 Hz, applied every four days or less) resulted in 63 to 76 percent greater tooth displacement compared to conventional orthodontic force (OF) alone. Micro-CT analysis revealed distinct bone remodeling patterns, with VF alone producing anabolic effects and combined OF and VF leading to synergistic changes in bone mineral density (BMD). Finite element modeling showed a correlation between von Mises stress distributions and BMD changes, supporting potential scalability to larger models and human application. To assess mechanical aspects of CAT, an orthodontic force tester (OFT) was developed. Quantitative analysis demonstrated that attachment geometry and placement significantly affect force systems. Fabrication-related issues such as trimming-induced variability (up to 36 percent deviation in moment) and material relaxation (22.9 percent force decay per cycle) were also identified, highlighting the importance of standardizing aligner production. These findings offer biologically and mechanically informed strategies to improve treatment efficiency and clinical predictability.
546
$a
English
590
$a
School code: 0183
650
# 4
$a
Dentistry.
$3
674038
653
# #
$a
Orthodontic treatment
690
$a
0567
710
2 #
$a
Purdue University.
$3
1184550
720
1
$a
Chen, Jie
$e
degree supervisor.
773
0 #
$t
Dissertations Abstracts International
$g
87-04B.
790
$a
0183
791
$a
Ph.D.
792
$a
2025
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32264807
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入