Language:
English
繁體中文
Help
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Imaging of Trabecular Microfracture ...
~
SpringerLink (Online service)
Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage/ by Yong-Whee Bahk.
Author:
Bahk, Yong-Whee.
Description:
XVII, 146 p. 166 illus., 121 illus. in color.online resource. :
Contained By:
Springer Nature eBook
Subject:
Nuclear Medicine. -
Online resource:
https://doi.org/10.1007/978-981-15-4466-8
ISBN:
9789811544668
Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage
Bahk, Yong-Whee.
Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage
[electronic resource] /by Yong-Whee Bahk. - 1st ed. 2020. - XVII, 146 p. 166 illus., 121 illus. in color.online resource.
1. Introduction -- 2. Pinhole Bone Scanning -- 3. Gamma Correction -- 4. Technical Processing of Gamma Correction -- 5. Gamma Correction Pinhole Bone Scan -- 6. Experimental Gamma Correction 99mTc-HDP Pinhole Bone Scan, Diagnosis of Trabecular Microfracture in Young Rats -- 7. Preoperative Confirmatory Imaging Diagnosis of Femoral Neck Fracture -- 8. Gamma Correction Pinhole Scan of Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 9. Hematoxylin-Eosin Stain of Calcifying Calluses in Trabecular Microfractures -- 10. Identification of Trabecular Microcalluses in GCPBS and H&E Stain -- 11. Quantitation of 99mTc-HDP Uptake in Microcallus Using Pixelized Method -- 12. Quantitation of Gamma Correction Pinhole Bone Scan and H&E Stain -- 13. Reciprocal Correlation of Shapes of Tracer Uptake and Findings of Surgical Specimen, GCPBS and H&E Stain -- 14. Morphobiochemical Diagnosis of Acute Trabecular Microcallus Using Gamma Correction 99mTc-HDP Pinhole Bone Scan with Histological Verification -- 15. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 16. Surgical Specimens from Human Subjects -- 17. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 18. Gamma Correction Pinhole Scanof Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 19. Gamma Correction Pinhole Bone Scan -- 20. Identification of Trabecular Microfractures in GCPBS and H&E Stain -- 21. Quantification of Micro-Fracture Tracer Uptake Using Pixelized Measurement -- 22. Overall Considerations -- 23. Precise Differntial Diagnosis of Acute Bone Marrow Edema and Hemorrhage and Trabecular Microfracture Using Nave and Gamma Correction Pinhole Bone Scans, NIH ImageJ Densitometry, and Pixelized -- 24. Micofracture Measurement -- 25. Introduction -- 26. Clinical Materials -- 27. Techniques of Seriated Nave and Gamma Correction Pinhole Bone Scanning and Reference Conventional Radiography and Corroborative Coronal FS T2 weighted MRI -- 28. NIH ImageJ Densitometry of 99mTc-HDP Uptake Intensity Measurement in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture on Seriated Naive and Gamma Correction Pinhole Bone Scans -- 29. Mathematic Measurement of Trabecular Microfracture Size with Unsuppressed 99mTc-HDP uptake -- 30. Differential 99mTc-HDP Uptake Intensity Measurement of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 31. Histopathological Validation -- 32. Differential Diagnosis of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 33. Innocuousness of Bone Marrow Edema to Intact Trabecula on Nave Pinhole Scan Showing Mild Tracer Uptake Which is Suppressed -- 34. Differential Image J Densitometry Intensity Values of 99mTc-HDP Uptake in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture -- 35. Fractured Trabeculae with Unsuppressed Enhanced Tracer Uptake -- 36. Innocuousness of Edema to Intact Trabecula and Injuriousness of Hemorrhage to Already Broken Trabecula -- 37. H&E Stain Validation of Additive Bone Marrow Hemorrhage Which Injures Already -- 38. NIH Image J Densitometric Analysis of an Old MR Image of Histologically Proven "Edemalike"Bone Marrow Change in Knee -- 39. Discussion -- 40. Summary and Conclusions.
This excellently illustrated monograph summarizes the updated fresh information on the theoretical, practical, and rapidly extended facets of gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan (99mTc-GCPBS) to MRI, CR, and MDCT. Basically, 99mTc-GCPBS is able to precisely visualize and quantitate callused trabecular microfracture (CTMF) which is as little as 200 μm in size. The extended gamma correction images can very neatly demonstrate CTMF on MRI, conventional radiography (CR), and multidetector computed tomography (MDCT). Whenever appropriate, histological correlation is provided in conjunction with fine gamma corrected images. In this setting, ACDSee 10 gamma correction MRI and CR have been found to offer a highly useful option that deserves wider clinical interest. In practice, gamma correction MRI, CR, and MDCT can distinctly visualize CTMF so that CTMF can be precisely measured simply using an optic lens. By comparison, the naïve MRI, for example, shows CTMF which measures as big as 2 mm in size. Furthermore, 99mTc-GCPBS can now differentiate bone marrow edema from hemorrhage using the visuospatial mathematic method, which includes the ImageJ of the NIH.
ISBN: 9789811544668
Standard No.: 10.1007/978-981-15-4466-8doiSubjects--Topical Terms:
673045
Nuclear Medicine.
LC Class. No.: R895-920
Dewey Class. No.: 616.07548
Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage
LDR
:05851nam a22003975i 4500
001
1021372
003
DE-He213
005
20200804064558.0
007
cr nn 008mamaa
008
210318s2020 si | s |||| 0|eng d
020
$a
9789811544668
$9
978-981-15-4466-8
024
7
$a
10.1007/978-981-15-4466-8
$2
doi
035
$a
978-981-15-4466-8
050
4
$a
R895-920
072
7
$a
MMN
$2
bicssc
072
7
$a
MED080000
$2
bisacsh
072
7
$a
MKR
$2
thema
082
0 4
$a
616.07548
$2
23
100
1
$a
Bahk, Yong-Whee.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1071567
245
1 0
$a
Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage
$h
[electronic resource] /
$c
by Yong-Whee Bahk.
250
$a
1st ed. 2020.
264
1
$a
Singapore :
$b
Springer Singapore :
$b
Imprint: Springer,
$c
2020.
300
$a
XVII, 146 p. 166 illus., 121 illus. in color.
$b
online resource.
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
347
$a
text file
$b
PDF
$2
rda
505
0
$a
1. Introduction -- 2. Pinhole Bone Scanning -- 3. Gamma Correction -- 4. Technical Processing of Gamma Correction -- 5. Gamma Correction Pinhole Bone Scan -- 6. Experimental Gamma Correction 99mTc-HDP Pinhole Bone Scan, Diagnosis of Trabecular Microfracture in Young Rats -- 7. Preoperative Confirmatory Imaging Diagnosis of Femoral Neck Fracture -- 8. Gamma Correction Pinhole Scan of Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 9. Hematoxylin-Eosin Stain of Calcifying Calluses in Trabecular Microfractures -- 10. Identification of Trabecular Microcalluses in GCPBS and H&E Stain -- 11. Quantitation of 99mTc-HDP Uptake in Microcallus Using Pixelized Method -- 12. Quantitation of Gamma Correction Pinhole Bone Scan and H&E Stain -- 13. Reciprocal Correlation of Shapes of Tracer Uptake and Findings of Surgical Specimen, GCPBS and H&E Stain -- 14. Morphobiochemical Diagnosis of Acute Trabecular Microcallus Using Gamma Correction 99mTc-HDP Pinhole Bone Scan with Histological Verification -- 15. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 16. Surgical Specimens from Human Subjects -- 17. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 18. Gamma Correction Pinhole Scanof Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 19. Gamma Correction Pinhole Bone Scan -- 20. Identification of Trabecular Microfractures in GCPBS and H&E Stain -- 21. Quantification of Micro-Fracture Tracer Uptake Using Pixelized Measurement -- 22. Overall Considerations -- 23. Precise Differntial Diagnosis of Acute Bone Marrow Edema and Hemorrhage and Trabecular Microfracture Using Nave and Gamma Correction Pinhole Bone Scans, NIH ImageJ Densitometry, and Pixelized -- 24. Micofracture Measurement -- 25. Introduction -- 26. Clinical Materials -- 27. Techniques of Seriated Nave and Gamma Correction Pinhole Bone Scanning and Reference Conventional Radiography and Corroborative Coronal FS T2 weighted MRI -- 28. NIH ImageJ Densitometry of 99mTc-HDP Uptake Intensity Measurement in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture on Seriated Naive and Gamma Correction Pinhole Bone Scans -- 29. Mathematic Measurement of Trabecular Microfracture Size with Unsuppressed 99mTc-HDP uptake -- 30. Differential 99mTc-HDP Uptake Intensity Measurement of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 31. Histopathological Validation -- 32. Differential Diagnosis of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 33. Innocuousness of Bone Marrow Edema to Intact Trabecula on Nave Pinhole Scan Showing Mild Tracer Uptake Which is Suppressed -- 34. Differential Image J Densitometry Intensity Values of 99mTc-HDP Uptake in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture -- 35. Fractured Trabeculae with Unsuppressed Enhanced Tracer Uptake -- 36. Innocuousness of Edema to Intact Trabecula and Injuriousness of Hemorrhage to Already Broken Trabecula -- 37. H&E Stain Validation of Additive Bone Marrow Hemorrhage Which Injures Already -- 38. NIH Image J Densitometric Analysis of an Old MR Image of Histologically Proven "Edemalike"Bone Marrow Change in Knee -- 39. Discussion -- 40. Summary and Conclusions.
520
$a
This excellently illustrated monograph summarizes the updated fresh information on the theoretical, practical, and rapidly extended facets of gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan (99mTc-GCPBS) to MRI, CR, and MDCT. Basically, 99mTc-GCPBS is able to precisely visualize and quantitate callused trabecular microfracture (CTMF) which is as little as 200 μm in size. The extended gamma correction images can very neatly demonstrate CTMF on MRI, conventional radiography (CR), and multidetector computed tomography (MDCT). Whenever appropriate, histological correlation is provided in conjunction with fine gamma corrected images. In this setting, ACDSee 10 gamma correction MRI and CR have been found to offer a highly useful option that deserves wider clinical interest. In practice, gamma correction MRI, CR, and MDCT can distinctly visualize CTMF so that CTMF can be precisely measured simply using an optic lens. By comparison, the naïve MRI, for example, shows CTMF which measures as big as 2 mm in size. Furthermore, 99mTc-GCPBS can now differentiate bone marrow edema from hemorrhage using the visuospatial mathematic method, which includes the ImageJ of the NIH.
650
1 4
$a
Nuclear Medicine.
$3
673045
650
0
$a
Nuclear medicine.
$3
673902
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer Nature eBook
776
0 8
$i
Printed edition:
$z
9789811544651
776
0 8
$i
Printed edition:
$z
9789811544675
776
0 8
$i
Printed edition:
$z
9789811544682
856
4 0
$u
https://doi.org/10.1007/978-981-15-4466-8
912
$a
ZDB-2-SME
912
$a
ZDB-2-SXM
950
$a
Medicine (SpringerNature-11650)
950
$a
Medicine (R0) (SpringerNature-43714)
based on 0 review(s)
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login