語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Implantable Optoelectronics for Neural Interfaces.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
Implantable Optoelectronics for Neural Interfaces./
作者:
Pollmann, Eric Hiroshi.
面頁冊數:
1 online resource (182 pages)
附註:
Source: Dissertations Abstracts International, Volume: 84-10, Section: B.
Contained By:
Dissertations Abstracts International84-10B.
標題:
Neurosciences. -
電子資源:
click for full text (PQDT)
ISBN:
9798379417239
Implantable Optoelectronics for Neural Interfaces.
Pollmann, Eric Hiroshi.
Implantable Optoelectronics for Neural Interfaces.
- 1 online resource (182 pages)
Source: Dissertations Abstracts International, Volume: 84-10, Section: B.
Thesis (Ph.D.)--Columbia University, 2023.
Includes bibliographical references
In neuroscience, optical techniques have become the leading method over electrophysiological techniques because of their ability to target defined populations upon tagging both for in vivo recordings using genetically encoded calcium or voltage indicators and stimulation using optogenetic opsins at the single neuronal level. Additionally, optical imaging has a smaller tissue displacement factor, the ratio of displaced neuronal tissue to field of view (FoV), thus accelerating the ability to simultaneously record from a larger volumes of neurons whereas electrophysiology arrays are limited in the total number of recordable neurons by the amount of sustained tissue damage. Conventional optical approaches, however, typically rely on microscopy techniques which require the subject to be head-fixed thus limiting the applicability especially at the chronic setting, raising the need for fully implantable optical interfaces. As a result, multiple lens-based miniature microscopes have been developed in academia and industry. Nevertheless, a truly implantable optical neurotechnology has remained intractable because traditional miniaturized fluorescence microscopes require an opening in the dura and skull that matches or exceeds the FoV and chronically extends outside the skull, resulting in a poor overall displacement factor. To overcome these limitations, I developed and characterized various implantable optoelectronic platforms designed to optically record from large neuronal FoVs in a minimally invasive implantable form factor. These works culminated in the SCOPe (Subdural CMOS Optical Probe) platform which was validated in multiple in vivo demonstrations involving mouse and nonhuman primate.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2024
Mode of access: World Wide Web
ISBN: 9798379417239Subjects--Topical Terms:
593561
Neurosciences.
Subjects--Index Terms:
Brain machine interfaceIndex Terms--Genre/Form:
554714
Electronic books.
Implantable Optoelectronics for Neural Interfaces.
LDR
:03126ntm a22004097 4500
001
1151803
005
20241118135825.5
006
m o d
007
cr mn ---uuuuu
008
250605s2023 xx obm 000 0 eng d
020
$a
9798379417239
035
$a
(MiAaPQ)AAI30319044
035
$a
AAI30319044
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Pollmann, Eric Hiroshi.
$3
1478632
245
1 0
$a
Implantable Optoelectronics for Neural Interfaces.
264
0
$c
2023
300
$a
1 online resource (182 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 84-10, Section: B.
500
$a
Advisor: Shepard, Kenneth L.
502
$a
Thesis (Ph.D.)--Columbia University, 2023.
504
$a
Includes bibliographical references
520
$a
In neuroscience, optical techniques have become the leading method over electrophysiological techniques because of their ability to target defined populations upon tagging both for in vivo recordings using genetically encoded calcium or voltage indicators and stimulation using optogenetic opsins at the single neuronal level. Additionally, optical imaging has a smaller tissue displacement factor, the ratio of displaced neuronal tissue to field of view (FoV), thus accelerating the ability to simultaneously record from a larger volumes of neurons whereas electrophysiology arrays are limited in the total number of recordable neurons by the amount of sustained tissue damage. Conventional optical approaches, however, typically rely on microscopy techniques which require the subject to be head-fixed thus limiting the applicability especially at the chronic setting, raising the need for fully implantable optical interfaces. As a result, multiple lens-based miniature microscopes have been developed in academia and industry. Nevertheless, a truly implantable optical neurotechnology has remained intractable because traditional miniaturized fluorescence microscopes require an opening in the dura and skull that matches or exceeds the FoV and chronically extends outside the skull, resulting in a poor overall displacement factor. To overcome these limitations, I developed and characterized various implantable optoelectronic platforms designed to optically record from large neuronal FoVs in a minimally invasive implantable form factor. These works culminated in the SCOPe (Subdural CMOS Optical Probe) platform which was validated in multiple in vivo demonstrations involving mouse and nonhuman primate.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2024
538
$a
Mode of access: World Wide Web
650
4
$a
Neurosciences.
$3
593561
650
4
$a
Biomedical engineering.
$3
588770
650
4
$a
Electrical engineering.
$3
596380
653
$a
Brain machine interface
653
$a
Integrated circuit design
653
$a
Co-packaged optics
653
$a
Fluorescence imaging
653
$a
In-vivo experiment
653
$a
Optogenetic stimulation
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0544
690
$a
0541
690
$a
0317
710
2
$a
Columbia University.
$b
Electrical Engineering.
$3
1179181
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
773
0
$t
Dissertations Abstracts International
$g
84-10B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30319044
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入