Dual SWIR Reflectance/Transillumination Imaging for Caries Detection.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
Dual SWIR Reflectance/Transillumination Imaging for Caries Detection./
作者:
Ng, Chung.
面頁冊數:
1 online resource (38 pages)
附註:
Source: Masters Abstracts International, Volume: 84-12.
Contained By:
Masters Abstracts International84-12.
標題:
Dentistry. -
電子資源:
click for full text (PQDT)
ISBN:
9798379620417
Dual SWIR Reflectance/Transillumination Imaging for Caries Detection.
Ng, Chung.
Dual SWIR Reflectance/Transillumination Imaging for Caries Detection.
- 1 online resource (38 pages)
Source: Masters Abstracts International, Volume: 84-12.
Thesis (M.S.)--University of California, San Francisco, 2023.
Includes bibliographical references
Short wavelength infrared (SWIR) and near-infrared (NIR) imaging methods have been in development for almost two decades for dental use. Due to the high transparency of enamel in the NIR, separate novel imaging configurations such as occlusal transillumination and cross-polarization reflectance imaging have been discovered to be useful in imaging interproximal and occlusal lesions, respectively. Novel clinical probes capable of acquiring simultaneous SWIR reflectance and occlusal transillumination images of lesions on tooth proximal and occlusal surfaces have recently been developed at UCSF. The dual probe is 3D-printed, and the imaging system uses a SWIR camera and fiber-optic light sources that use SWIR light at 1300-nm for occlusal transillumination and SWIR 1450-nm light for reflectance measurements. Previously, this dual probe was used to image extracted teeth with proximal and occlusal lesions, showing promising results verifying false positives using micro-CT images as a gold standard to assess performance. The purpose of this study is to determine the sensitivity and specificity of this novel probe on 40 human test subjects each with 2-4 premolars scheduled for extraction due to orthodontic purposes. In addition to imaging with the dual probe, visible intraoral photos of the teeth were taken prior to extraction. After extraction, radiographs of the teeth were taken, and samples were imaged using microradiography serving as the gold standard. The visible digital images and radiographs were assessed, and all samples were scored with the standardized ICDAS criteria. For the short-wave infrared images, contrast calculations were performed. The sensitivity and specificity were then calculated for visual examination, radiography, individual SWIR reflectance and occlusal transillumination and for combined SWIR reflectance and occlusal transillumination. Our study demonstrates for the first time that near simultaneous transillumination (1300-nm) and reflectance (1600-nm) video can be successfully acquired of lesions in real-time. Both imaging modalities had markedly higher sensitivity for lesions on proximal and occlusal surfaces compared to conventional methods (visual and radiographic images). Reflectance imaging at 1600-nm had significantly higher specificity than transillumination at 1300-nm.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2024
Mode of access: World Wide Web
ISBN: 9798379620417Subjects--Topical Terms:
674038
Dentistry.
Subjects--Index Terms:
CariesIndex Terms--Genre/Form:
554714
Electronic books.
Dual SWIR Reflectance/Transillumination Imaging for Caries Detection.
LDR
:03697ntm a22003977 4500
001
1152580
005
20241209114601.5
006
m o d
007
cr mn ---uuuuu
008
250605s2023 xx obm 000 0 eng d
020
$a
9798379620417
035
$a
(MiAaPQ)AAI30490754
035
$a
AAI30490754
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Ng, Chung.
$3
1479615
245
1 0
$a
Dual SWIR Reflectance/Transillumination Imaging for Caries Detection.
264
0
$c
2023
300
$a
1 online resource (38 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 84-12.
500
$a
Advisor: Fried, Daniel.
502
$a
Thesis (M.S.)--University of California, San Francisco, 2023.
504
$a
Includes bibliographical references
520
$a
Short wavelength infrared (SWIR) and near-infrared (NIR) imaging methods have been in development for almost two decades for dental use. Due to the high transparency of enamel in the NIR, separate novel imaging configurations such as occlusal transillumination and cross-polarization reflectance imaging have been discovered to be useful in imaging interproximal and occlusal lesions, respectively. Novel clinical probes capable of acquiring simultaneous SWIR reflectance and occlusal transillumination images of lesions on tooth proximal and occlusal surfaces have recently been developed at UCSF. The dual probe is 3D-printed, and the imaging system uses a SWIR camera and fiber-optic light sources that use SWIR light at 1300-nm for occlusal transillumination and SWIR 1450-nm light for reflectance measurements. Previously, this dual probe was used to image extracted teeth with proximal and occlusal lesions, showing promising results verifying false positives using micro-CT images as a gold standard to assess performance. The purpose of this study is to determine the sensitivity and specificity of this novel probe on 40 human test subjects each with 2-4 premolars scheduled for extraction due to orthodontic purposes. In addition to imaging with the dual probe, visible intraoral photos of the teeth were taken prior to extraction. After extraction, radiographs of the teeth were taken, and samples were imaged using microradiography serving as the gold standard. The visible digital images and radiographs were assessed, and all samples were scored with the standardized ICDAS criteria. For the short-wave infrared images, contrast calculations were performed. The sensitivity and specificity were then calculated for visual examination, radiography, individual SWIR reflectance and occlusal transillumination and for combined SWIR reflectance and occlusal transillumination. Our study demonstrates for the first time that near simultaneous transillumination (1300-nm) and reflectance (1600-nm) video can be successfully acquired of lesions in real-time. Both imaging modalities had markedly higher sensitivity for lesions on proximal and occlusal surfaces compared to conventional methods (visual and radiographic images). Reflectance imaging at 1600-nm had significantly higher specificity than transillumination at 1300-nm.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2024
538
$a
Mode of access: World Wide Web
650
4
$a
Dentistry.
$3
674038
650
4
$a
Medical imaging.
$3
1180167
653
$a
Caries
653
$a
Demineralization
653
$a
Reflectivity
653
$a
Teeth
653
$a
Short wavelength infrared
653
$a
Transillumination images
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0567
690
$a
0574
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
University of California, San Francisco.
$b
Oral and Craniofacial Sciences.
$3
1479616
773
0
$t
Masters Abstracts International
$g
84-12.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30490754
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入