語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Stimulation and recording electrodes...
~
Pour Aryan, Naser.
Stimulation and recording electrodes for neural prostheses
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Stimulation and recording electrodes for neural prostheses/ by Naser Pour Aryan, Hans Kaim, Albrecht Rothermel.
作者:
Pour Aryan, Naser.
其他作者:
Kaim, Hans.
出版者:
Cham :Springer International Publishing : : 2015.,
面頁冊數:
xii, 81 p. :ill. (some col.), digital ; : 24 cm.;
Contained By:
Springer eBooks
標題:
Neuroprostheses. -
電子資源:
http://dx.doi.org/10.1007/978-3-319-10052-4
ISBN:
9783319100524 (electronic bk.)
Stimulation and recording electrodes for neural prostheses
Pour Aryan, Naser.
Stimulation and recording electrodes for neural prostheses
[electronic resource] /by Naser Pour Aryan, Hans Kaim, Albrecht Rothermel. - Cham :Springer International Publishing :2015. - xii, 81 p. :ill. (some col.), digital ;24 cm. - SpringerBriefs in electrical and computer engineering,782191-8112 ;. - SpringerBriefs in electrical and computer engineering ;74..
Stimulation and recording electrodes: General concepts -- Irreversible and reversible redox reactions: Water window -- Charge balance and safe operation conditions -- Primary current distribution and electrode geometry -- Experiments hardware and methods -- Electrode materials: State-of-the-art and experiments -- The effect of the counter electrode on stimulation electrode lifetime -- Electrode modeling for titanium nitride, iridium and iridium oxide microelectrodes -- Summary.
This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.
ISBN: 9783319100524 (electronic bk.)
Standard No.: 10.1007/978-3-319-10052-4doiSubjects--Topical Terms:
1062758
Neuroprostheses.
LC Class. No.: R856
Dewey Class. No.: 610.28
Stimulation and recording electrodes for neural prostheses
LDR
:02192nam a2200325 a 4500
001
834353
003
DE-He213
005
20150603091143.0
006
m d
007
cr nn 008maaau
008
160421s2015 gw s 0 eng d
020
$a
9783319100524 (electronic bk.)
020
$a
9783319100517 (paper)
024
7
$a
10.1007/978-3-319-10052-4
$2
doi
035
$a
978-3-319-10052-4
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
R856
072
7
$a
TJFC
$2
bicssc
072
7
$a
TEC008010
$2
bisacsh
082
0 4
$a
610.28
$2
23
090
$a
R856
$b
.P877 2015
100
1
$a
Pour Aryan, Naser.
$3
1062485
245
1 0
$a
Stimulation and recording electrodes for neural prostheses
$h
[electronic resource] /
$c
by Naser Pour Aryan, Hans Kaim, Albrecht Rothermel.
260
$a
Cham :
$c
2015.
$b
Springer International Publishing :
$b
Imprint: Springer,
300
$a
xii, 81 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
490
1
$a
SpringerBriefs in electrical and computer engineering,
$x
2191-8112 ;
$v
78
505
0
$a
Stimulation and recording electrodes: General concepts -- Irreversible and reversible redox reactions: Water window -- Charge balance and safe operation conditions -- Primary current distribution and electrode geometry -- Experiments hardware and methods -- Electrode materials: State-of-the-art and experiments -- The effect of the counter electrode on stimulation electrode lifetime -- Electrode modeling for titanium nitride, iridium and iridium oxide microelectrodes -- Summary.
520
$a
This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.
650
0
$a
Neuroprostheses.
$3
1062758
650
0
$a
Microelectrodes.
$3
581308
650
1 4
$a
Engineering.
$3
561152
650
2 4
$a
Circuits and Systems.
$3
670901
650
2 4
$a
Biomedical Engineering.
$3
588771
700
1
$a
Kaim, Hans.
$3
1062756
700
1
$a
Rothermel, Albrecht.
$3
1062757
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer eBooks
830
0
$a
SpringerBriefs in electrical and computer engineering ;
$v
74.
$3
1023686
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-10052-4
950
$a
Engineering (Springer-11647)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入