Reliability of steel columns protect...
~
Zhang, Chao.
Reliability of steel columns protected by intumescent coatings subjected to natural fires
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Reliability of steel columns protected by intumescent coatings subjected to natural fires/ by Chao Zhang.
作者:
Zhang, Chao.
出版者:
Berlin, Heidelberg :Springer Berlin Heidelberg : : 2015.,
面頁冊數:
xxiv, 140 p. :ill., digital ; : 24 cm.;
Contained By:
Springer eBooks
標題:
Metal coating. -
電子資源:
http://dx.doi.org/10.1007/978-3-662-46379-6
ISBN:
9783662463796 (electronic bk.)
Reliability of steel columns protected by intumescent coatings subjected to natural fires
Zhang, Chao.
Reliability of steel columns protected by intumescent coatings subjected to natural fires
[electronic resource] /by Chao Zhang. - Berlin, Heidelberg :Springer Berlin Heidelberg :2015. - xxiv, 140 p. :ill., digital ;24 cm. - Springer theses,2190-5053. - Springer theses..
Introduction -- Fire Modeling -- Steel Temperature in Natural Fires -- Thermal Properties of Intumescent Coatings in Fire -- Behavior of Steel Columns in Fire -- Reliability Analysis -- Service Life of Intumescent Coatings -- Conclusions and Further Work.
This thesis studied the effect of aging of intumescent coatings (ICs) on the reliability of protected steel columns in fire condition and developed a probabilistic approach to assess the service life of ICs applied on steel columns. In the study, Monte Carlo simulations were conducted to obtain the reliability index or failure probability of steel columns protected by ICs subjected to compartment fires. The effect of aging of intumescent coatings on the failure probability of protected steel columns was investigated by using variable insulation property of intumescent coatings in the simulation. The test data on aging effect on insulation property of intumescent coatings from literature was used. Based on the reliability analysis, a probabilistic approach is given to determine the service life of intumescent coatings for steel columns. In that approach, the failure probability of the protected steel columns is compared with the target probability of the structural fire design. The approach can also be used for probabilistic analysis of steel columns protected by conventional inert fire protection materials.
ISBN: 9783662463796 (electronic bk.)
Standard No.: 10.1007/978-3-662-46379-6doiSubjects--Topical Terms:
943650
Metal coating.
LC Class. No.: TA633
Dewey Class. No.: 624.1
Reliability of steel columns protected by intumescent coatings subjected to natural fires
LDR
:02417nam a2200337 a 4500
001
836420
003
DE-He213
005
20150921134201.0
006
m d
007
cr nn 008maaau
008
160421s2015 gw s 0 eng d
020
$a
9783662463796 (electronic bk.)
020
$a
9783662463789 (paper)
024
7
$a
10.1007/978-3-662-46379-6
$2
doi
035
$a
978-3-662-46379-6
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TA633
072
7
$a
TNK
$2
bicssc
072
7
$a
TEC009020
$2
bisacsh
072
7
$a
TEC021000
$2
bisacsh
082
0 4
$a
624.1
$2
23
090
$a
TA633
$b
.Z63 20135
100
1
$a
Zhang, Chao.
$3
883105
245
1 0
$a
Reliability of steel columns protected by intumescent coatings subjected to natural fires
$h
[electronic resource] /
$c
by Chao Zhang.
260
$a
Berlin, Heidelberg :
$c
2015.
$b
Springer Berlin Heidelberg :
$b
Imprint: Springer,
300
$a
xxiv, 140 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
Springer theses,
$x
2190-5053
505
0
$a
Introduction -- Fire Modeling -- Steel Temperature in Natural Fires -- Thermal Properties of Intumescent Coatings in Fire -- Behavior of Steel Columns in Fire -- Reliability Analysis -- Service Life of Intumescent Coatings -- Conclusions and Further Work.
520
$a
This thesis studied the effect of aging of intumescent coatings (ICs) on the reliability of protected steel columns in fire condition and developed a probabilistic approach to assess the service life of ICs applied on steel columns. In the study, Monte Carlo simulations were conducted to obtain the reliability index or failure probability of steel columns protected by ICs subjected to compartment fires. The effect of aging of intumescent coatings on the failure probability of protected steel columns was investigated by using variable insulation property of intumescent coatings in the simulation. The test data on aging effect on insulation property of intumescent coatings from literature was used. Based on the reliability analysis, a probabilistic approach is given to determine the service life of intumescent coatings for steel columns. In that approach, the failure probability of the protected steel columns is compared with the target probability of the structural fire design. The approach can also be used for probabilistic analysis of steel columns protected by conventional inert fire protection materials.
650
0
$a
Metal coating.
$3
943650
650
0
$a
Structural engineering.
$3
557594
650
0
$a
Metal buildings
$x
Design and construction.
$3
1066535
650
1 4
$a
Engineering.
$3
561152
650
2 4
$a
Building Materials.
$3
671098
650
2 4
$a
Structural Materials.
$3
677176
650
2 4
$a
Quality Control, Reliability, Safety and Risk.
$3
671184
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer eBooks
830
0
$a
Springer theses.
$3
831604
856
4 0
$u
http://dx.doi.org/10.1007/978-3-662-46379-6
950
$a
Engineering (Springer-11647)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入