語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Collimator-based tracking with an ad...
~
SpringerLink (Online service)
Collimator-based tracking with an add-on multileaf collimator = modification of a commercial collimator system for realtime applications /
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Collimator-based tracking with an add-on multileaf collimator/ by Andreas Bohler.
其他題名:
modification of a commercial collimator system for realtime applications /
作者:
Bohler, Andreas.
出版者:
Wiesbaden :Springer Fachmedien Wiesbaden : : 2016.,
面頁冊數:
xiv, 53 p. :ill., digital ; : 24 cm.;
Contained By:
Springer eBooks
標題:
Radiotherapy - Equipment and supplies. -
電子資源:
http://dx.doi.org/10.1007/978-3-658-10658-4
ISBN:
9783658106584
Collimator-based tracking with an add-on multileaf collimator = modification of a commercial collimator system for realtime applications /
Bohler, Andreas.
Collimator-based tracking with an add-on multileaf collimator
modification of a commercial collimator system for realtime applications /[electronic resource] :by Andreas Bohler. - Wiesbaden :Springer Fachmedien Wiesbaden :2016. - xiv, 53 p. :ill., digital ;24 cm. - BestMedDiss. - BestMedDiss..
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical. Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it. Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets. Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
ISBN: 9783658106584
Standard No.: 10.1007/978-3-658-10658-4doiSubjects--Topical Terms:
1103230
Radiotherapy
--Equipment and supplies.
LC Class. No.: RM862.5
Dewey Class. No.: 615.842
Collimator-based tracking with an add-on multileaf collimator = modification of a commercial collimator system for realtime applications /
LDR
:02434nam a2200325 a 4500
001
861093
003
DE-He213
005
20160727142611.0
006
m d
007
cr nn 008maaau
008
170720s2016 gw s 0 eng d
020
$a
9783658106584
$q
(electronic bk.)
020
$a
9783658106577
$q
(paper)
024
7
$a
10.1007/978-3-658-10658-4
$2
doi
035
$a
978-3-658-10658-4
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RM862.5
072
7
$a
MJCL1
$2
bicssc
072
7
$a
MED080000
$2
bisacsh
082
0 4
$a
615.842
$2
23
090
$a
RM862.5
$b
.B676 2016
100
1
$a
Bohler, Andreas.
$3
1103228
245
1 0
$a
Collimator-based tracking with an add-on multileaf collimator
$h
[electronic resource] :
$b
modification of a commercial collimator system for realtime applications /
$c
by Andreas Bohler.
260
$a
Wiesbaden :
$c
2016.
$b
Springer Fachmedien Wiesbaden :
$b
Imprint: Springer,
300
$a
xiv, 53 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
BestMedDiss
505
0
$a
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
520
$a
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical. Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it. Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets. Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
650
0
$a
Radiotherapy
$x
Equipment and supplies.
$3
1103230
650
0
$a
Collimators (Optical instrument)
$3
1103231
650
1 4
$a
Medicine & Public Health.
$3
593949
650
2 4
$a
Radiotherapy.
$3
593952
650
2 4
$a
Oncology.
$3
593951
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer eBooks
830
0
$a
BestMedDiss.
$3
1103229
856
4 0
$u
http://dx.doi.org/10.1007/978-3-658-10658-4
950
$a
Medicine (Springer-11650)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入