語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Graphene Oxide Based Biosensing Plat...
~
Darbandi, Arash.
Graphene Oxide Based Biosensing Platform.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Graphene Oxide Based Biosensing Platform./
作者:
Darbandi, Arash.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2017,
面頁冊數:
57 p.
附註:
Source: Masters Abstracts International, Volume: 56-06.
Contained By:
Masters Abstracts International56-06(E).
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10644450
ISBN:
9780355176865
Graphene Oxide Based Biosensing Platform.
Darbandi, Arash.
Graphene Oxide Based Biosensing Platform.
- Ann Arbor : ProQuest Dissertations & Theses, 2017 - 57 p.
Source: Masters Abstracts International, Volume: 56-06.
Thesis (M.S.)--University of Illinois at Chicago, 2017.
The conjugation of nanomaterials with biomolecules has allowed for engineering at the nanoscale to build devices which help improve human health and environment. Graphene oxide, a two-dimensional carbon based nanomaterial, has been on the forefront of such endeavors through its use in biosensing and controlled drug release. Herein, graphene oxide is used as a substrate to anchor an aptamer based molecular beacon. Upon presence of mercury, the mercury sensitive aptamer undergoes a conformational change shortening the distance between an excited quantum dot and a quenching gold nanoparticle. As the distance between the two decreases, the efficiency of the fluorescence resonance energy transfer increases---decreasing the intensity of the system. The graphene oxide substrate behaves as a quencher as well, thus varying linker lengths separating the molecular beacon and graphene oxide were used to study the extent of its quenching. It was found at 51 base pairs, and 35 base pairs, the sensitivity of the system was like that of the molecular beacon without any graphene oxide present. At 14 base pairs the graphene oxide quenched the quantum dot's energy, leading to a decrease in sensor sensitivity. The system exhibited a linear relationship in the nanomolar range throughout all four sensors and the effect of ionic concentration on the performance was also investigated. The detection limit was found to be 16.5 nM, 38.4 nM, 9.45 nM, and 11.38 nM from the no graphene oxide to the 51 base pairs linker respectively.
ISBN: 9780355176865Subjects--Topical Terms:
588770
Biomedical engineering.
Graphene Oxide Based Biosensing Platform.
LDR
:02411nam a2200289 4500
001
890756
005
20180727091503.5
008
180907s2017 ||||||||||||||||| ||eng d
020
$a
9780355176865
035
$a
(MiAaPQ)AAI10644450
035
$a
(MiAaPQ)0799vireo:305Darbandi
035
$a
AAI10644450
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Darbandi, Arash.
$3
1148650
245
1 0
$a
Graphene Oxide Based Biosensing Platform.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2017
300
$a
57 p.
500
$a
Source: Masters Abstracts International, Volume: 56-06.
500
$a
Adviser: Michael Stroscio.
502
$a
Thesis (M.S.)--University of Illinois at Chicago, 2017.
520
$a
The conjugation of nanomaterials with biomolecules has allowed for engineering at the nanoscale to build devices which help improve human health and environment. Graphene oxide, a two-dimensional carbon based nanomaterial, has been on the forefront of such endeavors through its use in biosensing and controlled drug release. Herein, graphene oxide is used as a substrate to anchor an aptamer based molecular beacon. Upon presence of mercury, the mercury sensitive aptamer undergoes a conformational change shortening the distance between an excited quantum dot and a quenching gold nanoparticle. As the distance between the two decreases, the efficiency of the fluorescence resonance energy transfer increases---decreasing the intensity of the system. The graphene oxide substrate behaves as a quencher as well, thus varying linker lengths separating the molecular beacon and graphene oxide were used to study the extent of its quenching. It was found at 51 base pairs, and 35 base pairs, the sensitivity of the system was like that of the molecular beacon without any graphene oxide present. At 14 base pairs the graphene oxide quenched the quantum dot's energy, leading to a decrease in sensor sensitivity. The system exhibited a linear relationship in the nanomolar range throughout all four sensors and the effect of ionic concentration on the performance was also investigated. The detection limit was found to be 16.5 nM, 38.4 nM, 9.45 nM, and 11.38 nM from the no graphene oxide to the 51 base pairs linker respectively.
590
$a
School code: 0799.
650
4
$a
Biomedical engineering.
$3
588770
690
$a
0541
710
2
$a
University of Illinois at Chicago.
$b
Bioengineering.
$3
1148651
773
0
$t
Masters Abstracts International
$g
56-06(E).
790
$a
0799
791
$a
M.S.
792
$a
2017
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10644450
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入