語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Development of Smartphone based Opti...
~
ProQuest Information and Learning Co.
Development of Smartphone based Optical Device.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
Development of Smartphone based Optical Device./
作者:
Jung, Youngkee.
面頁冊數:
1 online resource (102 pages)
附註:
Source: Dissertation Abstracts International, Volume: 79-03(E), Section: B.
Contained By:
Dissertation Abstracts International79-03B(E).
標題:
Mechanical engineering. -
電子資源:
click for full text (PQDT)
ISBN:
9780355258271
Development of Smartphone based Optical Device.
Jung, Youngkee.
Development of Smartphone based Optical Device.
- 1 online resource (102 pages)
Source: Dissertation Abstracts International, Volume: 79-03(E), Section: B.
Thesis (Ph.D.)
Includes bibliographical references
Due to the economy of scale, smartphones are becoming more affordable while their computing powers are increasing dramatically every year. Here we propose a ubiquitous and portable instrument for analyte quantitation by utilizing the characteristics of typical smartphone imaging system and specific design of transducers for different applications. Three testbeds included in this work are: quantitative colorimetric analysis, ultra-low radiant flux detection, and portable spectrometer. As a proof-of-principle for each device, 3-D printed cradle and theoretical simulation with MATLAB have been implemented. First example utilizes the native CMOS camera with their respective RGB channel data and perform an analyte quantitation for typical lateral flow devices (LFD). Histogram analysis method has been employed to detect the analyte concentration and calibration results show good correlation between perceived color change and analyte concentration. The second example shows the possibility of using a conventional CMOS camera for pico Watt level photon flux detection. Since most of consumer grade CMOS cameras cannot detect this level of light intensity and their dark current are relatively higher, a new algorithm called NREA (Noise Reduction by Ensemble Averaging) algorithm was developed to effectively reduce the noise level and increase the SNR (signal to noise ratio). This technique is effective for bioanalytical assays that has lower flux intensity such as fluorescence and luminescence. As a proof-of-principle, we tested the device with Pseudomonas fluorescens M3A and achieved a limit of detection of high 10? CFU/ml. In addition to basic schematic of detection model, another experiment with a silicon photomultiplier (SiPM) has been studied for more sensitive light detectability. Based on both the laser experiment and tw bioluminescent experiments, named Pseudomonas fluorescens M3A and NanoLuc, we found that the miniSM based device has a superior ability than the smartphone to detect the low light intensity. Finally, smartphone based spectrometers have been developed and experiments have been performed to demonstrate its availability. Smartphone spectrometers were designed with two kinds of spectrometer functions, absorbance and reflection spectrometer. Based on the diffraction theory, the experimental results were compared with simulation results and demonstrated the feasibility as a spectrometer. Peak locations were calibrated with diode lasers in three wavelengths (405 nm, 532 nm and 635 nm) and specific software application was developed to capture a spectrum. A Biuret test was done to test its feasibility as an absorbance spectrometer. To show the possibility as a reflection spectrometer, the real meat test was done using a standard experimental process of meat freshness analysis.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2018
Mode of access: World Wide Web
ISBN: 9780355258271Subjects--Topical Terms:
557493
Mechanical engineering.
Index Terms--Genre/Form:
554714
Electronic books.
Development of Smartphone based Optical Device.
LDR
:04087ntm a2200349Ki 4500
001
908728
005
20180330125241.5
006
m o u
007
cr mn||||a|a||
008
190606s2017 xx obm 000 0 eng d
020
$a
9780355258271
035
$a
(MiAaPQ)AAI10608212
035
$a
(MiAaPQ)purdue:21795
035
$a
AAI10608212
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
099
$a
TUL
$f
hyy
$c
available through World Wide Web
100
1
$a
Jung, Youngkee.
$3
1178995
245
1 0
$a
Development of Smartphone based Optical Device.
264
0
$c
2017
300
$a
1 online resource (102 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertation Abstracts International, Volume: 79-03(E), Section: B.
500
$a
Advisers: Euiwon Bae; Galen King.
502
$a
Thesis (Ph.D.)
$c
Purdue University
$d
2017.
504
$a
Includes bibliographical references
520
$a
Due to the economy of scale, smartphones are becoming more affordable while their computing powers are increasing dramatically every year. Here we propose a ubiquitous and portable instrument for analyte quantitation by utilizing the characteristics of typical smartphone imaging system and specific design of transducers for different applications. Three testbeds included in this work are: quantitative colorimetric analysis, ultra-low radiant flux detection, and portable spectrometer. As a proof-of-principle for each device, 3-D printed cradle and theoretical simulation with MATLAB have been implemented. First example utilizes the native CMOS camera with their respective RGB channel data and perform an analyte quantitation for typical lateral flow devices (LFD). Histogram analysis method has been employed to detect the analyte concentration and calibration results show good correlation between perceived color change and analyte concentration. The second example shows the possibility of using a conventional CMOS camera for pico Watt level photon flux detection. Since most of consumer grade CMOS cameras cannot detect this level of light intensity and their dark current are relatively higher, a new algorithm called NREA (Noise Reduction by Ensemble Averaging) algorithm was developed to effectively reduce the noise level and increase the SNR (signal to noise ratio). This technique is effective for bioanalytical assays that has lower flux intensity such as fluorescence and luminescence. As a proof-of-principle, we tested the device with Pseudomonas fluorescens M3A and achieved a limit of detection of high 10? CFU/ml. In addition to basic schematic of detection model, another experiment with a silicon photomultiplier (SiPM) has been studied for more sensitive light detectability. Based on both the laser experiment and tw bioluminescent experiments, named Pseudomonas fluorescens M3A and NanoLuc, we found that the miniSM based device has a superior ability than the smartphone to detect the low light intensity. Finally, smartphone based spectrometers have been developed and experiments have been performed to demonstrate its availability. Smartphone spectrometers were designed with two kinds of spectrometer functions, absorbance and reflection spectrometer. Based on the diffraction theory, the experimental results were compared with simulation results and demonstrated the feasibility as a spectrometer. Peak locations were calibrated with diode lasers in three wavelengths (405 nm, 532 nm and 635 nm) and specific software application was developed to capture a spectrum. A Biuret test was done to test its feasibility as an absorbance spectrometer. To show the possibility as a reflection spectrometer, the real meat test was done using a standard experimental process of meat freshness analysis.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2018
538
$a
Mode of access: World Wide Web
650
4
$a
Mechanical engineering.
$3
557493
650
4
$a
Optics.
$3
595336
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0548
690
$a
0752
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
Purdue University.
$b
Mechanical Engineering.
$3
845672
773
0
$t
Dissertation Abstracts International
$g
79-03B(E).
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10608212
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入