語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Textile-Based Electrochemical Sensor...
~
Michigan State University.
Textile-Based Electrochemical Sensors and Batteries for Wearable Biosensing.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
Textile-Based Electrochemical Sensors and Batteries for Wearable Biosensing./
作者:
Liu, Xiyuan.
面頁冊數:
1 online resource (111 pages)
附註:
Source: Dissertation Abstracts International, Volume: 79-01(E), Section: B.
Contained By:
Dissertation Abstracts International79-01B(E).
標題:
Mechanical engineering. -
電子資源:
click for full text (PQDT)
ISBN:
9780355169454
Textile-Based Electrochemical Sensors and Batteries for Wearable Biosensing.
Liu, Xiyuan.
Textile-Based Electrochemical Sensors and Batteries for Wearable Biosensing.
- 1 online resource (111 pages)
Source: Dissertation Abstracts International, Volume: 79-01(E), Section: B.
Thesis (Ph.D.)
Includes bibliographical references
Wearable biosensors have gained tremendous attention in the past decade due to their capacity for ex vivo physical and biochemical measurements of important physiological parameters including heart rate, oxygenation of the blood, respiration rate, skin temperature, bodily motion, brain activity, blood pressure, and sweat composition. This has been achieved, in part, through recent developments in flexible sensors and miniature electronics, which can offer high sensing performance on a compact, lightweight platform. While much progress has been made in this field, existing wearable chemical sensors are prone to damage due to mechanical deformation and/or require bulky, rigid electronic components. In this work, we explored the development of robust, textile-based electrochemical sensors and batteries for wearable sensing applications. In particular, a novel method for fabricating flexible electrochemical sensors was introduced by utilizing embroidery. Using this technique, conductive thread-based electrodes were fabricated onto various types of textile and fabrics, which could be made with customized geometries and configurations to accommodate commercial or custom electrochemical instrumentation. For proof-of-concept, embroidered biosensors were used for measurements of glucose and lactate in buffer and whole blood samples, which offered excellent analytical performance, good resiliency against mechanical stress and superior repeatability. We also adapted this technology for generating embroidered sensors onto gauze for rapid measurements of uric acid, a biomarker of wound healing. We demonstrated that this embroidered gauze sensor maintained high accuracy up to 7 hours for continuous wound monitoring.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2018
Mode of access: World Wide Web
ISBN: 9780355169454Subjects--Topical Terms:
557493
Mechanical engineering.
Index Terms--Genre/Form:
554714
Electronic books.
Textile-Based Electrochemical Sensors and Batteries for Wearable Biosensing.
LDR
:04992ntm a2200373Ki 4500
001
908739
005
20180330125241.5
006
m o u
007
cr mn||||a|a||
008
190606s2017 xx obm 000 0 eng d
020
$a
9780355169454
035
$a
(MiAaPQ)AAI10620117
035
$a
(MiAaPQ)grad.msu:15550
035
$a
AAI10620117
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
099
$a
TUL
$f
hyy
$c
available through World Wide Web
100
1
$a
Liu, Xiyuan.
$3
1179009
245
1 0
$a
Textile-Based Electrochemical Sensors and Batteries for Wearable Biosensing.
264
0
$c
2017
300
$a
1 online resource (111 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertation Abstracts International, Volume: 79-01(E), Section: B.
500
$a
Adviser: Peter B. Lillehoj.
502
$a
Thesis (Ph.D.)
$c
Michigan State University
$d
2017.
504
$a
Includes bibliographical references
520
$a
Wearable biosensors have gained tremendous attention in the past decade due to their capacity for ex vivo physical and biochemical measurements of important physiological parameters including heart rate, oxygenation of the blood, respiration rate, skin temperature, bodily motion, brain activity, blood pressure, and sweat composition. This has been achieved, in part, through recent developments in flexible sensors and miniature electronics, which can offer high sensing performance on a compact, lightweight platform. While much progress has been made in this field, existing wearable chemical sensors are prone to damage due to mechanical deformation and/or require bulky, rigid electronic components. In this work, we explored the development of robust, textile-based electrochemical sensors and batteries for wearable sensing applications. In particular, a novel method for fabricating flexible electrochemical sensors was introduced by utilizing embroidery. Using this technique, conductive thread-based electrodes were fabricated onto various types of textile and fabrics, which could be made with customized geometries and configurations to accommodate commercial or custom electrochemical instrumentation. For proof-of-concept, embroidered biosensors were used for measurements of glucose and lactate in buffer and whole blood samples, which offered excellent analytical performance, good resiliency against mechanical stress and superior repeatability. We also adapted this technology for generating embroidered sensors onto gauze for rapid measurements of uric acid, a biomarker of wound healing. We demonstrated that this embroidered gauze sensor maintained high accuracy up to 7 hours for continuous wound monitoring.
520
$a
We also explored the development of liquid-activated textile batteries as a lightweight, flexible power source for textile biosensors. Two generations of batteries, the first utilizing thin film metal electrodes and the second utilizing screen-printed electrodes, were designed, fabricated and tested. These batteries are designed to turn on upon exposure to small amounts of liquid (~30 microL per cell) and turn off after being completely dried, thus facilitating autonomous operation. Additionally, this battery can be reactivated simply by adding more liquid to the cell(s). Through optimizing various battery parameters, a steady output voltage of 1.3 V was achieved from a single cell, which exhibited discharging times of 100 min and 50 min for loading currents of 1 microA and 50 microA, respectively. Batteries with higher voltages and currents were obtained by connecting multiple cells in series or parallel.
520
$a
Towards a fully integrated, wearable "smart diaper" sensing platform, we developed a textile biosensing system consisting of a screen-printed, liquid-activated battery and electrochemical sensor integrated with a miniature detection circuit. This device was used for quantitative measurements of xanthine oxidase (XOx), a biomarker correlated with urinary tract infections, in spiked buffer samples, which exhibited good linearity and accuracy. We also analyzed urine samples from patients with positive urine cultures using this device, which could detect XOx at concentrations between 0 U/L to 16,000 U/L, demonstrating the clinical usefulness of this platform. In conclusion, the results and technological advancements presented in this dissertation will provide researchers with new insights into the design and fabrication of textile-based chemical sensors and batteries, as well as their integration with miniature electronics, towards the realization of fully integrated, robust, wearable biosensing platforms.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2018
538
$a
Mode of access: World Wide Web
650
4
$a
Mechanical engineering.
$3
557493
650
4
$a
Engineering.
$3
561152
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0548
690
$a
0537
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
Michigan State University.
$b
Mechanical Engineering.
$3
845689
773
0
$t
Dissertation Abstracts International
$g
79-01B(E).
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10620117
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入