語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Integrated energy system for a high ...
~
Jaczko, Kristen.
Integrated energy system for a high performance building.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
Integrated energy system for a high performance building./
作者:
Jaczko, Kristen.
面頁冊數:
1 online resource (299 pages)
附註:
Source: Dissertation Abstracts International, Volume: 75-06C.
Contained By:
Dissertation Abstracts International75-06C.
標題:
Civil engineering. -
電子資源:
click for full text (PQDT)
Integrated energy system for a high performance building.
Jaczko, Kristen.
Integrated energy system for a high performance building.
- 1 online resource (299 pages)
Source: Dissertation Abstracts International, Volume: 75-06C.
Thesis (M.A.Sc.)
Includes bibliographical references
Integrated energy systems have the potential to reduce of the energy consumption of residential buildings in Canada. These systems incorporate components to meet the building heating, cooling and domestic hot water load into a single system in order to reduce energy losses. An integrated energy system, consisting of a variable speed heat pump, cold and hot thermal storage tanks, a photovoltaic/thermal (PV/T) collector array and a battery bank, was designed for the Queen's Solar Design Team's (QSDT) test house. The system uses a radiant floor to provide space- heating and sensible cooling and a dedicated outdoor air system provides ventilation and dehumidifies the incoming fresh air. The test house, the Queen's Solar Education Centre (QSEC), and the integrated energy system were both modelled in TRNSYS. Additionally, a new TRNSYS Type was developed to model the PV/T collectors, enabling the modeling of the collection of energy from the ambient air. A parametric study was carried out in TRNSYS to investigate the effect of various parameters on the overall energy performance of the system. These parameters included the PV/T array size and the slope of the collectors, the heat pump source and load-side inlet temperature setpoints, the compressor speed control and the size of the thermal storage tanks and the battery bank. The controls of the heat pump were found to have a large impact on the performance of the integrated energy system. For example, a low evaporator setpoint improved the overall free energy ratio (FER) of the system but the heat pump performance was lowered. Reducing the heat loss of the PV/T panels was not found to have a large effect on the system performance however, as the heat pump is able to lower the inlet collector fluid temperature, thus reducing thermal losses. From the results of the sensitivity study, a recommended system model was created and this system had a predicted FER of 77.9% in Kingston, Ontario, neglecting the energy consumption of circulation pumps and fans. Simulations of the recommended integrated energy system were also performed in several other Canadian cities and the predicted FER was above 60% in all except for the most northern city investigated, Yellowknife. Thus, the integrated energy system has the potential of reducing the energy consumption of residential buildings in Canada.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2018
Mode of access: World Wide Web
Subjects--Topical Terms:
561339
Civil engineering.
Index Terms--Genre/Form:
554714
Electronic books.
Integrated energy system for a high performance building.
LDR
:03618ntm a2200349Ki 4500
001
910617
005
20180517123958.5
006
m o u
007
cr mn||||a|a||
008
190606s2017 xx obm 000 0 eng d
035
$a
(MiAaPQ)AAI10706601
035
$a
(MiAaPQ)QueensUCan197422824
035
$a
AAI10706601
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
099
$a
TUL
$f
hyy
$c
available through World Wide Web
100
1
$a
Jaczko, Kristen.
$3
1181996
245
1 0
$a
Integrated energy system for a high performance building.
264
0
$c
2017
300
$a
1 online resource (299 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertation Abstracts International, Volume: 75-06C.
500
$a
Adviser: Stephen Harrison.
502
$a
Thesis (M.A.Sc.)
$c
Queen's University (Canada)
$d
2017.
504
$a
Includes bibliographical references
520
$a
Integrated energy systems have the potential to reduce of the energy consumption of residential buildings in Canada. These systems incorporate components to meet the building heating, cooling and domestic hot water load into a single system in order to reduce energy losses. An integrated energy system, consisting of a variable speed heat pump, cold and hot thermal storage tanks, a photovoltaic/thermal (PV/T) collector array and a battery bank, was designed for the Queen's Solar Design Team's (QSDT) test house. The system uses a radiant floor to provide space- heating and sensible cooling and a dedicated outdoor air system provides ventilation and dehumidifies the incoming fresh air. The test house, the Queen's Solar Education Centre (QSEC), and the integrated energy system were both modelled in TRNSYS. Additionally, a new TRNSYS Type was developed to model the PV/T collectors, enabling the modeling of the collection of energy from the ambient air. A parametric study was carried out in TRNSYS to investigate the effect of various parameters on the overall energy performance of the system. These parameters included the PV/T array size and the slope of the collectors, the heat pump source and load-side inlet temperature setpoints, the compressor speed control and the size of the thermal storage tanks and the battery bank. The controls of the heat pump were found to have a large impact on the performance of the integrated energy system. For example, a low evaporator setpoint improved the overall free energy ratio (FER) of the system but the heat pump performance was lowered. Reducing the heat loss of the PV/T panels was not found to have a large effect on the system performance however, as the heat pump is able to lower the inlet collector fluid temperature, thus reducing thermal losses. From the results of the sensitivity study, a recommended system model was created and this system had a predicted FER of 77.9% in Kingston, Ontario, neglecting the energy consumption of circulation pumps and fans. Simulations of the recommended integrated energy system were also performed in several other Canadian cities and the predicted FER was above 60% in all except for the most northern city investigated, Yellowknife. Thus, the integrated energy system has the potential of reducing the energy consumption of residential buildings in Canada.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2018
538
$a
Mode of access: World Wide Web
650
4
$a
Civil engineering.
$3
561339
650
4
$a
Architectural engineering.
$3
1180400
650
4
$a
Energy.
$3
784773
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0543
690
$a
0462
690
$a
0791
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
Queen's University (Canada).
$3
1148613
773
0
$t
Dissertation Abstracts International
$g
75-06C.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10706601
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入