語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Formulation and Testing of Biodegrad...
~
ProQuest Information and Learning Co.
Formulation and Testing of Biodegradable Polymeric Coating on Zinc Wires in Cardiovascular Stent Application.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
Formulation and Testing of Biodegradable Polymeric Coating on Zinc Wires in Cardiovascular Stent Application./
作者:
Arab Shomali, Avishan.
面頁冊數:
1 online resource (78 pages)
附註:
Source: Masters Abstracts International, Volume: 56-04.
標題:
Biomedical engineering. -
電子資源:
click for full text (PQDT)
ISBN:
9781369820430
Formulation and Testing of Biodegradable Polymeric Coating on Zinc Wires in Cardiovascular Stent Application.
Arab Shomali, Avishan.
Formulation and Testing of Biodegradable Polymeric Coating on Zinc Wires in Cardiovascular Stent Application.
- 1 online resource (78 pages)
Source: Masters Abstracts International, Volume: 56-04.
Thesis (M.S.)--Michigan Technological University, 2017.
Includes bibliographical references
Biodegradable and biocompatible poly (L-lactic-acid) (PLLA) coating was applied on a modified zinc (Zn) substrate by dip coating, with the intent to delay the bio-corrosion and slow the degradation rate of zinc substrate. 3-(Trimethoxysilyl) propyl methacrylate (MPS) was used for modification of the zinc substrate for promoting the adhesion between the metallic substrate and the polymer coating. It is hypothesized that the delay in Zn biodegradation could be useful in the first several weeks to prevent the early loss of mechanical integrity of the endovascular stent and to improve the healing process of the diseased vascular site. The PLLA coating was used in this study because of its biodegradability, favorable degradation rate, hydrophobicity and favorable mechanical properties. Static immersion, electrochemical and inductively coupled plasma (ICP) tests were used to investigate the degradation behavior of a polymer coated modified Zn substrate. Two uniform polymer layers with thickness of 1 and 3 mum were coated on the Zn substrate. The potentiodynamic polarization test indicated that the 1 mum polymer coated specimen has higher corrosion potentials (Ecorr) and lower corrosion cur rents (icorr) in the simulated body fluid (SBF) compared to the uncoated Zn. AC impedance measurement in EIS test also demonstrated a significant improvement in the impedance and polarization resistance of the coated Zn substrate. However, after 10 days of immersion in the SBF, the impedance reduced drastically which is indicative of a coating degradation and penetration of the electrolyte to the zinc substrate. Immersion degradation studies showed that the cross-sectional area (CSA) reduction and penetration rate (PR) for polymer coated samples are 5 times smaller than for uncoated samples after 14 days of immersion in SBF solution. Results of the ICP method indicated an increase in the release of the Zn2+ to the solution for the uncoated Zn, while the 1 mum PLLA coated sample demonstrated much slower release rate of Zn2+ and the concentration of Zn ion during the 14 days' immersion in SBF was almost the same. In in vivo studies, the polymer-coated Zn and uncoated Zn samples were implanted into the abdominal aorta of the rats and then directed into the lumen. The explants were extracted after 0.5 to 6 months. The results of in vivo study indicated that the uncoated samples have approximately two times higher CSA reduction and PR in comparison to the coated samples during first 4.5 months. After 4.5 months, the CSA reduction and PR increased significantly. However, the histological analysis of the biological tissue surrounding samples showed a reduction in biocompatibility of the polymer coated samples indicated by increasing cell toxicity and neointimal hyperplasia.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2018
Mode of access: World Wide Web
ISBN: 9781369820430Subjects--Topical Terms:
588770
Biomedical engineering.
Index Terms--Genre/Form:
554714
Electronic books.
Formulation and Testing of Biodegradable Polymeric Coating on Zinc Wires in Cardiovascular Stent Application.
LDR
:03988ntm a2200325K 4500
001
914132
005
20180703084422.5
006
m o u
007
cr mn||||a|a||
008
190606s2017 xx obm 000 0 eng d
020
$a
9781369820430
035
$a
(MiAaPQ)AAI10266577
035
$a
(MiAaPQ)michigantech:11276
035
$a
AAI10266577
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
100
1
$a
Arab Shomali, Avishan.
$3
1187247
245
1 0
$a
Formulation and Testing of Biodegradable Polymeric Coating on Zinc Wires in Cardiovascular Stent Application.
264
0
$c
2017
300
$a
1 online resource (78 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 56-04.
500
$a
Adviser: Jaroslaw W. Drelich.
502
$a
Thesis (M.S.)--Michigan Technological University, 2017.
504
$a
Includes bibliographical references
520
$a
Biodegradable and biocompatible poly (L-lactic-acid) (PLLA) coating was applied on a modified zinc (Zn) substrate by dip coating, with the intent to delay the bio-corrosion and slow the degradation rate of zinc substrate. 3-(Trimethoxysilyl) propyl methacrylate (MPS) was used for modification of the zinc substrate for promoting the adhesion between the metallic substrate and the polymer coating. It is hypothesized that the delay in Zn biodegradation could be useful in the first several weeks to prevent the early loss of mechanical integrity of the endovascular stent and to improve the healing process of the diseased vascular site. The PLLA coating was used in this study because of its biodegradability, favorable degradation rate, hydrophobicity and favorable mechanical properties. Static immersion, electrochemical and inductively coupled plasma (ICP) tests were used to investigate the degradation behavior of a polymer coated modified Zn substrate. Two uniform polymer layers with thickness of 1 and 3 mum were coated on the Zn substrate. The potentiodynamic polarization test indicated that the 1 mum polymer coated specimen has higher corrosion potentials (Ecorr) and lower corrosion cur rents (icorr) in the simulated body fluid (SBF) compared to the uncoated Zn. AC impedance measurement in EIS test also demonstrated a significant improvement in the impedance and polarization resistance of the coated Zn substrate. However, after 10 days of immersion in the SBF, the impedance reduced drastically which is indicative of a coating degradation and penetration of the electrolyte to the zinc substrate. Immersion degradation studies showed that the cross-sectional area (CSA) reduction and penetration rate (PR) for polymer coated samples are 5 times smaller than for uncoated samples after 14 days of immersion in SBF solution. Results of the ICP method indicated an increase in the release of the Zn2+ to the solution for the uncoated Zn, while the 1 mum PLLA coated sample demonstrated much slower release rate of Zn2+ and the concentration of Zn ion during the 14 days' immersion in SBF was almost the same. In in vivo studies, the polymer-coated Zn and uncoated Zn samples were implanted into the abdominal aorta of the rats and then directed into the lumen. The explants were extracted after 0.5 to 6 months. The results of in vivo study indicated that the uncoated samples have approximately two times higher CSA reduction and PR in comparison to the coated samples during first 4.5 months. After 4.5 months, the CSA reduction and PR increased significantly. However, the histological analysis of the biological tissue surrounding samples showed a reduction in biocompatibility of the polymer coated samples indicated by increasing cell toxicity and neointimal hyperplasia.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2018
538
$a
Mode of access: World Wide Web
650
4
$a
Biomedical engineering.
$3
588770
650
4
$a
Materials science.
$3
557839
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0541
690
$a
0794
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
Michigan Technological University.
$b
Materials Science and Engineering.
$3
1182428
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10266577
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入