語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Development of a Simplified Heat and...
~
ProQuest Information and Learning Co.
Development of a Simplified Heat and Moisture Transfer Model for Residential Buildings.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
Development of a Simplified Heat and Moisture Transfer Model for Residential Buildings./
作者:
Kim, Joowook.
面頁冊數:
1 online resource (330 pages)
附註:
Source: Dissertation Abstracts International, Volume: 79-02(E), Section: B.
標題:
Architectural engineering. -
電子資源:
click for full text (PQDT)
ISBN:
9780355231670
Development of a Simplified Heat and Moisture Transfer Model for Residential Buildings.
Kim, Joowook.
Development of a Simplified Heat and Moisture Transfer Model for Residential Buildings.
- 1 online resource (330 pages)
Source: Dissertation Abstracts International, Volume: 79-02(E), Section: B.
Thesis (Ph.D.)--University of Colorado at Boulder, 2017.
Includes bibliographical references
A large number of building energy simulation programs are used to evaluate indoor conditions and energy performance of buildings. Every building energy modeling tool calculates the heat and moisture exchange among the outdoor environment, the building envelope, and indoor environments as a fundamental component of heating, ventilating, and air conditioning (HVAC) loads. While all tools account for moisture flow through the envelope by infiltration, almost no users calculate moisture diffusion through the envelope or moisture storage in the building due to excessive computation time and unavailable material properties. However, research has shown, and work in this dissertation has confirmed, that significant errors in energy consumption predictions occur when moisture exchange is ignored, especially in hot and humid climates. This dissertation explores the impact of moisture exchange in building energy models and develops recommendations for improving simplified moisture exchange calculations under circumstances where the errors are the greatest.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2018
Mode of access: World Wide Web
ISBN: 9780355231670Subjects--Topical Terms:
1180400
Architectural engineering.
Index Terms--Genre/Form:
554714
Electronic books.
Development of a Simplified Heat and Moisture Transfer Model for Residential Buildings.
LDR
:06435ntm a2200385K 4500
001
914435
005
20180712070705.5
006
m o u
007
cr mn||||a|a||
008
190606s2017 xx obm 000 0 eng d
020
$a
9780355231670
035
$a
(MiAaPQ)AAI10607409
035
$a
(MiAaPQ)colorado:15035
035
$a
AAI10607409
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
100
1
$a
Kim, Joowook.
$3
1187693
245
1 0
$a
Development of a Simplified Heat and Moisture Transfer Model for Residential Buildings.
264
0
$c
2017
300
$a
1 online resource (330 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertation Abstracts International, Volume: 79-02(E), Section: B.
500
$a
Adviser: Michael J. Brandemuehl.
502
$a
Thesis (Ph.D.)--University of Colorado at Boulder, 2017.
504
$a
Includes bibliographical references
520
$a
A large number of building energy simulation programs are used to evaluate indoor conditions and energy performance of buildings. Every building energy modeling tool calculates the heat and moisture exchange among the outdoor environment, the building envelope, and indoor environments as a fundamental component of heating, ventilating, and air conditioning (HVAC) loads. While all tools account for moisture flow through the envelope by infiltration, almost no users calculate moisture diffusion through the envelope or moisture storage in the building due to excessive computation time and unavailable material properties. However, research has shown, and work in this dissertation has confirmed, that significant errors in energy consumption predictions occur when moisture exchange is ignored, especially in hot and humid climates. This dissertation explores the impact of moisture exchange in building energy models and develops recommendations for improving simplified moisture exchange calculations under circumstances where the errors are the greatest.
520
$a
A research model has been developed to model detailed heat and moisture transfer in building envelopes, based on the HAMT model in EnergyPlus, which allows for the examination of both vapor and liquid transport mechanisms. The detailed model is validated through international benchmark tests and is used as a reference model to test simpler methods. Models for conduction transfer function (CTF) and effective mean penetration depth (EMPD) methods have also been developed.
520
$a
The research explored the opportunities to improve existing simplified moisture exchange models, specifically the heat and moisture transfer function (MTF) methods and the EMPD method. The MTF method accounts for transport of moisture vapor, but ignores liquid transport mechanism. An analysis was conducted to assess the impact of liquid transport on overall heat and mass transfer under various external environmental conditions for walls made of different building construction materials. Results indicate that liquid transport mechanism can have a significant impact on moisture flow through some construction materials, specifically concrete and gypsum, at high relative humidity. However, sensible and latent fluxes on the inside surface of multi-layer walls are not significantly impacted by the presence of liquid transport in the heat and moisture transfer calculations model. It is concluded that changes to the MTF model to account for liquid transport are not warranted.
520
$a
The EMPD model accounts for cyclic moisture storage at the surface of building materials and assemblies. As an extension of the conventional EMPD method, which accounts for buffering only on the inside surface, a two-sided moisture penetration depth model is proposed and evaluated how much the EMPD model at the external surface would influence thermal and moisture transfer at the inside surface. The results indicate that the two-sided EMPD model has no significant impact on inside sensible and latent heat fluxes.
520
$a
During the research, it was observed that moisture transport through building envelope assemblies, as opposed to moisture buffering in the assemblies, is usually very small. In fact, in most cases, it may not be necessary to account for moisture transport through the assemblies. This thesis proposes a simple assessment method to evaluate the sensitivity of HVAC loads to moisture transfer through constructions under different external conditions (temperature, humidity, and solar radiation). The methodology uses the ratio of latent heat flux and sensible heat flux, which is estimated using the mean values of temperature, vapor pressure, and sensible and latent resistances. The method is validated using the detailed heat and mass transfer model. The method can be used as a pre-simulation screening tool to assess whether moisture flux is expected to be significant.
520
$a
The one typical building construction assembly that shows high sensitivity to moisture flux is the ceiling in residential and light commercial construction, comprising painted gypsum and fiberglass insulation, separating the occupied zone and the attic. With relatively little moisture storage capacity, it is proposed that the ceiling moisture flux could be modeled with a simple steady-state moisture flux (SSMF) method. Dynamic performance can be improved by using time-averaged boundary conditions over twelve hours.
520
$a
Case studies for building performance with different heat and moisture transfer models were performed to investigate the contribution of the proposed SSMF method. A prototype residential buildings were analyzed in three cities, Miami (hot-humid), Atlanta (mixed-humid), and Chicago (cool-humid). The results suggest that the effect of the SSMF model is limited during the heating-dominated periods. On the other hand, for the cooling-dominated periods in hot and humid climates, the SSMF model was effective at reducing the error between conventional models and the reference heat and mass transfer model. For Miami, when the SSMF model is applied, modeling errors in wall surface total heat flux were reduced by up to a factor of ten.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2018
538
$a
Mode of access: World Wide Web
650
4
$a
Architectural engineering.
$3
1180400
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0462
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
University of Colorado at Boulder.
$b
Civil Engineering.
$3
1178930
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10607409
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入