The Reliability and Validity of Meas...
~
Bradford, Luke.
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power.
紀錄類型:
書目-語言資料,手稿 : Monograph/item
正題名/作者:
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power./
作者:
Bradford, Luke.
面頁冊數:
1 online resource (38 pages)
附註:
Source: Masters Abstracts International, Volume: 56-05.
Contained By:
Masters Abstracts International56-05(E).
標題:
Kinesiology. -
電子資源:
click for full text (PQDT)
ISBN:
9780355272970
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power.
Bradford, Luke.
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power.
- 1 online resource (38 pages)
Source: Masters Abstracts International, Volume: 56-05.
Thesis (M.S.Ed.)--University of Kansas, 2017.
Includes bibliographical references
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power The primary purpose of this paper is to validate a 3-D motion capture system as a reliable and valid measurement tool to be used in the practical setting for measuring bar velocity and mechanical power output. One resistance-trained, male college student participated in this study, performing ten sets of one repetition at loads of 30, 40, 50, 60, 70, and 80% of his 1 repetition maximum (1 RM) for the barbell back squat exercise. Each repetition was simultaneously recorded with a 3-D camera (EliteForm PowerTracker; EliteForm, Lincoln, Nebraska), a tether based position transducer (gold standard), and a tether-based external dynamometer. Power values were derived using the bar velocity and the system mass (external load + 88% of body mass). Both Mean and Peak Velocity and Mean and Peak Power values were used to compare the measurement devices. In addition to linear regression, and correlation data, Bland-Altman plots (Tukey mean difference analyses) were created to measure agreement in the relative difference of values from each system. There were significant correlations (r > .80) between all 3 methods, but were highest in mean velocity and peak velocity. Mean velocity and mean power are shown to be within the limits of agreement when comparing the 3-D camera system and LPT, while peak velocity and peak power are outside of the limits of agreement. However, a comparison of 3-D camera system and external dynamometer, shows that all 4 variables were within 95% limits of agreement. Overall, the technology in question offers a reliable means of assessing velocity and power measurements in the practical setting.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2018
Mode of access: World Wide Web
ISBN: 9780355272970Subjects--Topical Terms:
721210
Kinesiology.
Index Terms--Genre/Form:
554714
Electronic books.
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power.
LDR
:02916ntm a2200337Ki 4500
001
920101
005
20181129115903.5
006
m o u
007
cr mn||||a|a||
008
190606s2017 xx obm 000 0 eng d
020
$a
9780355272970
035
$a
(MiAaPQ)AAI10616907
035
$a
(MiAaPQ)ku:15547
035
$a
AAI10616907
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Bradford, Luke.
$3
1194811
245
1 4
$a
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power.
264
0
$c
2017
300
$a
1 online resource (38 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 56-05.
500
$a
Adviser: Andrew C. Fry.
502
$a
Thesis (M.S.Ed.)--University of Kansas, 2017.
504
$a
Includes bibliographical references
520
$a
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power The primary purpose of this paper is to validate a 3-D motion capture system as a reliable and valid measurement tool to be used in the practical setting for measuring bar velocity and mechanical power output. One resistance-trained, male college student participated in this study, performing ten sets of one repetition at loads of 30, 40, 50, 60, 70, and 80% of his 1 repetition maximum (1 RM) for the barbell back squat exercise. Each repetition was simultaneously recorded with a 3-D camera (EliteForm PowerTracker; EliteForm, Lincoln, Nebraska), a tether based position transducer (gold standard), and a tether-based external dynamometer. Power values were derived using the bar velocity and the system mass (external load + 88% of body mass). Both Mean and Peak Velocity and Mean and Peak Power values were used to compare the measurement devices. In addition to linear regression, and correlation data, Bland-Altman plots (Tukey mean difference analyses) were created to measure agreement in the relative difference of values from each system. There were significant correlations (r > .80) between all 3 methods, but were highest in mean velocity and peak velocity. Mean velocity and mean power are shown to be within the limits of agreement when comparing the 3-D camera system and LPT, while peak velocity and peak power are outside of the limits of agreement. However, a comparison of 3-D camera system and external dynamometer, shows that all 4 variables were within 95% limits of agreement. Overall, the technology in question offers a reliable means of assessing velocity and power measurements in the practical setting.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2018
538
$a
Mode of access: World Wide Web
650
4
$a
Kinesiology.
$3
721210
650
4
$a
Physical education.
$3
1179721
655
7
$a
Electronic books.
$2
local
$3
554714
690
$a
0575
690
$a
0523
710
2
$a
ProQuest Information and Learning Co.
$3
1178819
710
2
$a
University of Kansas.
$b
Health, Sport and Exercise Sciences.
$3
1185629
773
0
$t
Masters Abstracts International
$g
56-05(E).
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10616907
$z
click for full text (PQDT)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入