Language:
English
繁體中文
Help
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Dynamic isolation technologies in ne...
~
Zhou, Bin.
Dynamic isolation technologies in negative pressure isolation wards
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Dynamic isolation technologies in negative pressure isolation wards/ by Zhonglin Xu, Bin Zhou.
Author:
Xu, Zhonglin.
other author:
Zhou, Bin.
Published:
Singapore :Springer Singapore : : 2017.,
Description:
x, 216 p. :ill., digital ; : 24 cm.;
Contained By:
Springer eBooks
Subject:
Hospital buildings - Heating and ventilation. -
Online resource:
http://dx.doi.org/10.1007/978-981-10-2923-3
ISBN:
9789811029233
Dynamic isolation technologies in negative pressure isolation wards
Xu, Zhonglin.
Dynamic isolation technologies in negative pressure isolation wards
[electronic resource] /by Zhonglin Xu, Bin Zhou. - Singapore :Springer Singapore :2017. - x, 216 p. :ill., digital ;24 cm.
Importance of negative pressure isolation ward -- Three misunderstandings in design process of negative pressure isolation ward -- Principle and technology of dynamic isolation -- Air distribution design in negative pressure isolation ward -- Determination of air change rate in negative pressure isolation ward -- Safety of exhaust and return air is prerequisite -- Design essentials for negative pressure isolation ward.
This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach. This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas.
ISBN: 9789811029233
Standard No.: 10.1007/978-981-10-2923-3doiSubjects--Topical Terms:
1248818
Hospital buildings
--Heating and ventilation.
LC Class. No.: RA969.4
Dewey Class. No.: 614.46
Dynamic isolation technologies in negative pressure isolation wards
LDR
:02163nam a2200313 a 4500
001
957313
003
DE-He213
005
20170615155111.0
006
m d
007
cr nn 008maaau
008
201118s2017 si s 0 eng d
020
$a
9789811029233
$q
(electronic bk.)
020
$a
9789811029226
$q
(paper)
024
7
$a
10.1007/978-981-10-2923-3
$2
doi
035
$a
978-981-10-2923-3
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RA969.4
072
7
$a
TN
$2
bicssc
072
7
$a
TEC009020
$2
bisacsh
082
0 4
$a
614.46
$2
23
090
$a
RA969.4
$b
.X8 2017
100
1
$a
Xu, Zhonglin.
$3
1021163
245
1 0
$a
Dynamic isolation technologies in negative pressure isolation wards
$h
[electronic resource] /
$c
by Zhonglin Xu, Bin Zhou.
260
$a
Singapore :
$c
2017.
$b
Springer Singapore :
$b
Imprint: Springer,
300
$a
x, 216 p. :
$b
ill., digital ;
$c
24 cm.
505
0
$a
Importance of negative pressure isolation ward -- Three misunderstandings in design process of negative pressure isolation ward -- Principle and technology of dynamic isolation -- Air distribution design in negative pressure isolation ward -- Determination of air change rate in negative pressure isolation ward -- Safety of exhaust and return air is prerequisite -- Design essentials for negative pressure isolation ward.
520
$a
This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach. This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas.
650
0
$a
Hospital buildings
$x
Heating and ventilation.
$3
1248818
650
0
$a
Isolation (Hospital care)
$3
1248819
650
1 4
$a
Engineering.
$3
561152
650
2 4
$a
Building Physics, HVAC.
$3
1020217
650
2 4
$a
Fluid- and Aerodynamics.
$3
768779
650
2 4
$a
Atmospheric Protection/Air Quality Control/Air Pollution.
$3
668446
650
2 4
$a
Practice and Hospital Management.
$3
1103102
700
1
$a
Zhou, Bin.
$3
1248817
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer eBooks
856
4 0
$u
http://dx.doi.org/10.1007/978-981-10-2923-3
950
$a
Engineering (Springer-11647)
based on 0 review(s)
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login