語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Stimulation and Recording Electrodes...
~
Pour Aryan, Naser.
Stimulation and Recording Electrodes for Neural Prostheses
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Stimulation and Recording Electrodes for Neural Prostheses/ by Naser Pour Aryan, Hans Kaim, Albrecht Rothermel.
作者:
Pour Aryan, Naser.
其他作者:
Kaim, Hans.
面頁冊數:
XII, 81 p. 58 illus., 36 illus. in color.online resource. :
Contained By:
Springer Nature eBook
標題:
Electronic circuits. -
電子資源:
https://doi.org/10.1007/978-3-319-10052-4
ISBN:
9783319100524
Stimulation and Recording Electrodes for Neural Prostheses
Pour Aryan, Naser.
Stimulation and Recording Electrodes for Neural Prostheses
[electronic resource] /by Naser Pour Aryan, Hans Kaim, Albrecht Rothermel. - 1st ed. 2015. - XII, 81 p. 58 illus., 36 illus. in color.online resource. - SpringerBriefs in Electrical and Computer Engineering,2191-8112. - SpringerBriefs in Electrical and Computer Engineering,.
Stimulation and recording electrodes: General concepts -- Irreversible and reversible redox reactions: Water window -- Charge balance and safe operation conditions -- Primary current distribution and electrode geometry -- Experiments hardware and methods -- Electrode materials: State-of-the-art and experiments -- The effect of the counter electrode on stimulation electrode lifetime -- Electrode modeling for titanium nitride, iridium and iridium oxide microelectrodes -- Summary.
This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.
ISBN: 9783319100524
Standard No.: 10.1007/978-3-319-10052-4doiSubjects--Topical Terms:
563332
Electronic circuits.
LC Class. No.: TK7888.4
Dewey Class. No.: 621.3815
Stimulation and Recording Electrodes for Neural Prostheses
LDR
:02549nam a22003975i 4500
001
963696
003
DE-He213
005
20200701193242.0
007
cr nn 008mamaa
008
201211s2015 gw | s |||| 0|eng d
020
$a
9783319100524
$9
978-3-319-10052-4
024
7
$a
10.1007/978-3-319-10052-4
$2
doi
035
$a
978-3-319-10052-4
050
4
$a
TK7888.4
072
7
$a
TJFC
$2
bicssc
072
7
$a
TEC008010
$2
bisacsh
072
7
$a
TJFC
$2
thema
082
0 4
$a
621.3815
$2
23
100
1
$a
Pour Aryan, Naser.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1062485
245
1 0
$a
Stimulation and Recording Electrodes for Neural Prostheses
$h
[electronic resource] /
$c
by Naser Pour Aryan, Hans Kaim, Albrecht Rothermel.
250
$a
1st ed. 2015.
264
1
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2015.
300
$a
XII, 81 p. 58 illus., 36 illus. in color.
$b
online resource.
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
347
$a
text file
$b
PDF
$2
rda
490
1
$a
SpringerBriefs in Electrical and Computer Engineering,
$x
2191-8112
505
0
$a
Stimulation and recording electrodes: General concepts -- Irreversible and reversible redox reactions: Water window -- Charge balance and safe operation conditions -- Primary current distribution and electrode geometry -- Experiments hardware and methods -- Electrode materials: State-of-the-art and experiments -- The effect of the counter electrode on stimulation electrode lifetime -- Electrode modeling for titanium nitride, iridium and iridium oxide microelectrodes -- Summary.
520
$a
This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.
650
0
$a
Electronic circuits.
$3
563332
650
0
$a
Biomedical engineering.
$3
588770
650
1 4
$a
Circuits and Systems.
$3
670901
650
2 4
$a
Biomedical Engineering and Bioengineering.
$3
1211019
700
1
$a
Kaim, Hans.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1062756
700
1
$a
Rothermel, Albrecht.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1062757
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer Nature eBook
776
0 8
$i
Printed edition:
$z
9783319100517
776
0 8
$i
Printed edition:
$z
9783319100531
830
0
$a
SpringerBriefs in Electrical and Computer Engineering,
$x
2191-8112
$3
1253713
856
4 0
$u
https://doi.org/10.1007/978-3-319-10052-4
912
$a
ZDB-2-ENG
912
$a
ZDB-2-SXE
950
$a
Engineering (SpringerNature-11647)
950
$a
Engineering (R0) (SpringerNature-43712)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入