語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Remote Powering and Data Communicati...
~
Kilinc, Enver Gurhan.
Remote Powering and Data Communication for Implanted Biomedical Systems
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Remote Powering and Data Communication for Implanted Biomedical Systems/ by Enver Gurhan Kilinc, Catherine Dehollain, Franco Maloberti.
作者:
Kilinc, Enver Gurhan.
其他作者:
Dehollain, Catherine.
面頁冊數:
X, 146 p. 126 illus., 116 illus. in color.online resource. :
Contained By:
Springer Nature eBook
標題:
Electronic circuits. -
電子資源:
https://doi.org/10.1007/978-3-319-21179-4
ISBN:
9783319211794
Remote Powering and Data Communication for Implanted Biomedical Systems
Kilinc, Enver Gurhan.
Remote Powering and Data Communication for Implanted Biomedical Systems
[electronic resource] /by Enver Gurhan Kilinc, Catherine Dehollain, Franco Maloberti. - 1st ed. 2016. - X, 146 p. 126 illus., 116 illus. in color.online resource. - Analog Circuits and Signal Processing,1311872-082X ;. - Analog Circuits and Signal Processing,.
Introduction -- Remote Powering -- Magnetic power transfer -- Power management -- Data Communication -- Implantable Monitor Systems -- System Integration and Packaging.
This book describes new circuits and systems for implantable biomedical applications and explains the design of a batteryless, remotely-powered implantable micro-system, designed for long-term patient monitoring. Following new trends in implantable biomedical applications, the authors demonstrate a system which is capable of efficient, remote powering and reliable data communication. Novel architecture and design methodologies are used to transfer power with a low-power, optimized inductive link and data is transmitted by a reliable communication link. Additionally, an electro-mechanical solution is presented for tracking and monitoring the implantable system, while the patient is mobile. · Describes practical example of an implantable batteryless biomedical system; · Analyzes and compares various energy harvesting and power transfer methods; · Describes design of remote powering link and data communication of the implantable system, comparing different scenarios for the optimal solution.
ISBN: 9783319211794
Standard No.: 10.1007/978-3-319-21179-4doiSubjects--Topical Terms:
563332
Electronic circuits.
LC Class. No.: TK7888.4
Dewey Class. No.: 621.3815
Remote Powering and Data Communication for Implanted Biomedical Systems
LDR
:02699nam a22004095i 4500
001
972282
003
DE-He213
005
20200629203535.0
007
cr nn 008mamaa
008
201211s2016 gw | s |||| 0|eng d
020
$a
9783319211794
$9
978-3-319-21179-4
024
7
$a
10.1007/978-3-319-21179-4
$2
doi
035
$a
978-3-319-21179-4
050
4
$a
TK7888.4
072
7
$a
TJFC
$2
bicssc
072
7
$a
TEC008010
$2
bisacsh
072
7
$a
TJFC
$2
thema
082
0 4
$a
621.3815
$2
23
100
1
$a
Kilinc, Enver Gurhan.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1102661
245
1 0
$a
Remote Powering and Data Communication for Implanted Biomedical Systems
$h
[electronic resource] /
$c
by Enver Gurhan Kilinc, Catherine Dehollain, Franco Maloberti.
250
$a
1st ed. 2016.
264
1
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2016.
300
$a
X, 146 p. 126 illus., 116 illus. in color.
$b
online resource.
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
347
$a
text file
$b
PDF
$2
rda
490
1
$a
Analog Circuits and Signal Processing,
$x
1872-082X ;
$v
131
505
0
$a
Introduction -- Remote Powering -- Magnetic power transfer -- Power management -- Data Communication -- Implantable Monitor Systems -- System Integration and Packaging.
520
$a
This book describes new circuits and systems for implantable biomedical applications and explains the design of a batteryless, remotely-powered implantable micro-system, designed for long-term patient monitoring. Following new trends in implantable biomedical applications, the authors demonstrate a system which is capable of efficient, remote powering and reliable data communication. Novel architecture and design methodologies are used to transfer power with a low-power, optimized inductive link and data is transmitted by a reliable communication link. Additionally, an electro-mechanical solution is presented for tracking and monitoring the implantable system, while the patient is mobile. · Describes practical example of an implantable batteryless biomedical system; · Analyzes and compares various energy harvesting and power transfer methods; · Describes design of remote powering link and data communication of the implantable system, comparing different scenarios for the optimal solution.
650
0
$a
Electronic circuits.
$3
563332
650
0
$a
Biomedical engineering.
$3
588770
650
1 4
$a
Circuits and Systems.
$3
670901
650
2 4
$a
Biomedical Engineering and Bioengineering.
$3
1211019
650
2 4
$a
Electronic Circuits and Devices.
$3
782968
700
1
$a
Dehollain, Catherine.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1102662
700
1
$a
Maloberti, Franco.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1102663
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer Nature eBook
776
0 8
$i
Printed edition:
$z
9783319211787
776
0 8
$i
Printed edition:
$z
9783319211800
776
0 8
$i
Printed edition:
$z
9783319372419
830
0
$a
Analog Circuits and Signal Processing,
$x
1872-082X
$3
1254348
856
4 0
$u
https://doi.org/10.1007/978-3-319-21179-4
912
$a
ZDB-2-ENG
912
$a
ZDB-2-SXE
950
$a
Engineering (SpringerNature-11647)
950
$a
Engineering (R0) (SpringerNature-43712)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入