語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Towards Offline PET Monitoring at a ...
~
SpringerLink (Online service)
Towards Offline PET Monitoring at a Cyclotron-Based Proton Therapy Facility = Experiments and Monte Carlo Simulations /
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Towards Offline PET Monitoring at a Cyclotron-Based Proton Therapy Facility/ by Matthias Würl.
其他題名:
Experiments and Monte Carlo Simulations /
作者:
Würl, Matthias.
面頁冊數:
XV, 86 p. 30 illus., 10 illus. in color.online resource. :
Contained By:
Springer Nature eBook
標題:
Nuclear physics. -
電子資源:
https://doi.org/10.1007/978-3-658-13168-5
ISBN:
9783658131685
Towards Offline PET Monitoring at a Cyclotron-Based Proton Therapy Facility = Experiments and Monte Carlo Simulations /
Würl, Matthias.
Towards Offline PET Monitoring at a Cyclotron-Based Proton Therapy Facility
Experiments and Monte Carlo Simulations /[electronic resource] :by Matthias Würl. - 1st ed. 2016. - XV, 86 p. 30 illus., 10 illus. in color.online resource. - BestMasters,2625-3577. - BestMasters,.
Monte Carlo Modeling of a Clinical Proton Beam -- Low-Dose Envelope and Field Size Factor -- PET Activation Studies.
Matthias Würl presents two essential steps to implement offline PET monitoring of proton dose delivery at a clinical facility, namely the setting up of an accurate Monte Carlo model of the clinical beamline and the experimental validation of positron emitter production cross-sections. In the first part, the field size dependence of the dose output is described for scanned proton beams. Both the Monte Carlo and an analytical computational beam model were able to accurately predict target dose, while the latter tends to overestimate dose in normal tissue. In the second part, the author presents PET measurements of different phantom materials, which were activated by the proton beam. The results indicate that for an irradiation with a high number of protons for the sake of good statistics, dead time losses of the PET scanner may become important and lead to an underestimation of positron-emitter production yields. Contents Monte Carlo Modeling of a Clinical Proton Beam Low-Dose Envelope and Field Size Factor PET Activation Studies Target Groups Researchers and students in the field of medical physics with focus on particle therapy Medical physicists at proton therapy facilities The Author Matthias Würl wrote his Master’s Thesis at the chair of Medical Physics at the Ludwig-Maximilians University Munich. He is now a PhD student at the same department, working on transmission imaging with laser-accelerated ions.
ISBN: 9783658131685
Standard No.: 10.1007/978-3-658-13168-5doiSubjects--Topical Terms:
591618
Nuclear physics.
LC Class. No.: QC770-798
Dewey Class. No.: 539.7
Towards Offline PET Monitoring at a Cyclotron-Based Proton Therapy Facility = Experiments and Monte Carlo Simulations /
LDR
:02965nam a22003975i 4500
001
977875
003
DE-He213
005
20200629162257.0
007
cr nn 008mamaa
008
201211s2016 gw | s |||| 0|eng d
020
$a
9783658131685
$9
978-3-658-13168-5
024
7
$a
10.1007/978-3-658-13168-5
$2
doi
035
$a
978-3-658-13168-5
050
4
$a
QC770-798
072
7
$a
PHP
$2
bicssc
072
7
$a
SCI051000
$2
bisacsh
072
7
$a
PHP
$2
thema
082
0 4
$a
539.7
$2
23
100
1
$a
Würl, Matthias.
$e
author.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1271479
245
1 0
$a
Towards Offline PET Monitoring at a Cyclotron-Based Proton Therapy Facility
$h
[electronic resource] :
$b
Experiments and Monte Carlo Simulations /
$c
by Matthias Würl.
250
$a
1st ed. 2016.
264
1
$a
Wiesbaden :
$b
Springer Fachmedien Wiesbaden :
$b
Imprint: Springer Spektrum,
$c
2016.
300
$a
XV, 86 p. 30 illus., 10 illus. in color.
$b
online resource.
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
347
$a
text file
$b
PDF
$2
rda
490
1
$a
BestMasters,
$x
2625-3577
505
0
$a
Monte Carlo Modeling of a Clinical Proton Beam -- Low-Dose Envelope and Field Size Factor -- PET Activation Studies.
520
$a
Matthias Würl presents two essential steps to implement offline PET monitoring of proton dose delivery at a clinical facility, namely the setting up of an accurate Monte Carlo model of the clinical beamline and the experimental validation of positron emitter production cross-sections. In the first part, the field size dependence of the dose output is described for scanned proton beams. Both the Monte Carlo and an analytical computational beam model were able to accurately predict target dose, while the latter tends to overestimate dose in normal tissue. In the second part, the author presents PET measurements of different phantom materials, which were activated by the proton beam. The results indicate that for an irradiation with a high number of protons for the sake of good statistics, dead time losses of the PET scanner may become important and lead to an underestimation of positron-emitter production yields. Contents Monte Carlo Modeling of a Clinical Proton Beam Low-Dose Envelope and Field Size Factor PET Activation Studies Target Groups Researchers and students in the field of medical physics with focus on particle therapy Medical physicists at proton therapy facilities The Author Matthias Würl wrote his Master’s Thesis at the chair of Medical Physics at the Ludwig-Maximilians University Munich. He is now a PhD student at the same department, working on transmission imaging with laser-accelerated ions.
650
0
$a
Nuclear physics.
$3
591618
650
0
$a
Mathematical physics.
$3
527831
650
0
$a
Biophysics.
$3
581576
650
0
$a
Biological physics.
$3
1253579
650
1 4
$a
Particle and Nuclear Physics.
$3
769262
650
2 4
$a
Theoretical, Mathematical and Computational Physics.
$3
768900
650
2 4
$a
Biological and Medical Physics, Biophysics.
$3
1113305
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer Nature eBook
776
0 8
$i
Printed edition:
$z
9783658131678
776
0 8
$i
Printed edition:
$z
9783658131692
830
0
$a
BestMasters,
$x
2625-3577
$3
1253531
856
4 0
$u
https://doi.org/10.1007/978-3-658-13168-5
912
$a
ZDB-2-PHA
912
$a
ZDB-2-SXP
950
$a
Physics and Astronomy (SpringerNature-11651)
950
$a
Physics and Astronomy (R0) (SpringerNature-43715)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入