Clinical Low Field Strength Magnetic...
~
SpringerLink (Online service)
Clinical Low Field Strength Magnetic Resonance Imaging = A Practical Guide to Accessible MRI /
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Clinical Low Field Strength Magnetic Resonance Imaging/ by Hans-Martin Klein.
其他題名:
A Practical Guide to Accessible MRI /
作者:
Klein, Hans-Martin.
面頁冊數:
XV, 156 p. 114 illus., 55 illus. in color.online resource. :
Contained By:
Springer Nature eBook
標題:
Radiology. -
電子資源:
https://doi.org/10.1007/978-3-319-16516-5
ISBN:
9783319165165
Clinical Low Field Strength Magnetic Resonance Imaging = A Practical Guide to Accessible MRI /
Klein, Hans-Martin.
Clinical Low Field Strength Magnetic Resonance Imaging
A Practical Guide to Accessible MRI /[electronic resource] :by Hans-Martin Klein. - 1st ed. 2016. - XV, 156 p. 114 illus., 55 illus. in color.online resource.
Introduction -- Site planning: Room Planning -- RF Protection -- Energy Supply -- Cooling Supply -- magnet Installation -- Safety Considerations: Static Field -- Gradient Field -- RF Field -- Coils: Solenoid / Helmholtz Coils -- Send-/Receive Coils -- Phased Array Coils -- Multi-Channel Technology -- Imaging Technique: k-space -- Image resolution -- Signal-Noise Ratio / Contract-Noise Ratio -- Imaging time -- Spin Echo -- Fast Spin Echo -- Fast Gradient Echo -- Hybrid Imaging -- 3D Imaging -- Gradient Performance -- Fat saturation -- Diffusion Imaging -- Angiographic techniques -- Contrast Agents -- Image Quality Optimization: Number of excitations -- Slice Thickness -- Slice profile -- Interlacing -- Slice Orientation -- Field of view -- Matrix -- Partial Fourrier -- Interpolation -- Parallel Imaging -- Artifacts -- Postprocessing -- Clinical Imaging: Head -- Spine -- Joints -- Vascular Imaging -- Neck -- Thorax -- Abdomen -- Functional Imaging -- Cardiac Imaging -- Future Developments.
This book covers all aspects of low field MRI, describing its advantages, problems, and prerequisites. Individual chapters are devoted to site planning, safety considerations, coils, imaging technique, image quality optimization, the imaging of different anatomic regions, and likely future developments. The factors that must be borne in mind when selecting a low field system are clearly identified, and detailed attention is paid to the applications for which such a system is adequate. The focus on high field systems has led to a situation where only a few systems with field strengths lower than 0.5 T survive. Some of these systems possess high field features such as multichannel coils and strong gradients; furthermore, sequence technology and image processing techniques taken from higher field strength systems have resulted in impressive imaging capabilities. While 1.5-T systems will probably continue to remain the standard, low field systems offer advantages such as the feasibility of dynamic joint examinations, improvement of T1 contrast, reduction of “missile effects”, and decreased radiofrequency exposure. Low field strength MRI consequently has the potential to contribute to optimal patient management and, given comparable image quality, its application may become an issue of patient safety. This book will be an invaluable asset to all who are involved in planning and/or running a low field strength MRI facility.
ISBN: 9783319165165
Standard No.: 10.1007/978-3-319-16516-5doiSubjects--Topical Terms:
673943
Radiology.
LC Class. No.: R895-920
Dewey Class. No.: 616.0757
Clinical Low Field Strength Magnetic Resonance Imaging = A Practical Guide to Accessible MRI /
LDR
:03820nam a22003975i 4500
001
978127
003
DE-He213
005
20200701094218.0
007
cr nn 008mamaa
008
201211s2016 gw | s |||| 0|eng d
020
$a
9783319165165
$9
978-3-319-16516-5
024
7
$a
10.1007/978-3-319-16516-5
$2
doi
035
$a
978-3-319-16516-5
050
4
$a
R895-920
072
7
$a
MMPH
$2
bicssc
072
7
$a
MED019000
$2
bisacsh
072
7
$a
MKSH
$2
thema
082
0 4
$a
616.0757
$2
23
100
1
$a
Klein, Hans-Martin.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1103044
245
1 0
$a
Clinical Low Field Strength Magnetic Resonance Imaging
$h
[electronic resource] :
$b
A Practical Guide to Accessible MRI /
$c
by Hans-Martin Klein.
250
$a
1st ed. 2016.
264
1
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2016.
300
$a
XV, 156 p. 114 illus., 55 illus. in color.
$b
online resource.
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
347
$a
text file
$b
PDF
$2
rda
505
0
$a
Introduction -- Site planning: Room Planning -- RF Protection -- Energy Supply -- Cooling Supply -- magnet Installation -- Safety Considerations: Static Field -- Gradient Field -- RF Field -- Coils: Solenoid / Helmholtz Coils -- Send-/Receive Coils -- Phased Array Coils -- Multi-Channel Technology -- Imaging Technique: k-space -- Image resolution -- Signal-Noise Ratio / Contract-Noise Ratio -- Imaging time -- Spin Echo -- Fast Spin Echo -- Fast Gradient Echo -- Hybrid Imaging -- 3D Imaging -- Gradient Performance -- Fat saturation -- Diffusion Imaging -- Angiographic techniques -- Contrast Agents -- Image Quality Optimization: Number of excitations -- Slice Thickness -- Slice profile -- Interlacing -- Slice Orientation -- Field of view -- Matrix -- Partial Fourrier -- Interpolation -- Parallel Imaging -- Artifacts -- Postprocessing -- Clinical Imaging: Head -- Spine -- Joints -- Vascular Imaging -- Neck -- Thorax -- Abdomen -- Functional Imaging -- Cardiac Imaging -- Future Developments.
520
$a
This book covers all aspects of low field MRI, describing its advantages, problems, and prerequisites. Individual chapters are devoted to site planning, safety considerations, coils, imaging technique, image quality optimization, the imaging of different anatomic regions, and likely future developments. The factors that must be borne in mind when selecting a low field system are clearly identified, and detailed attention is paid to the applications for which such a system is adequate. The focus on high field systems has led to a situation where only a few systems with field strengths lower than 0.5 T survive. Some of these systems possess high field features such as multichannel coils and strong gradients; furthermore, sequence technology and image processing techniques taken from higher field strength systems have resulted in impressive imaging capabilities. While 1.5-T systems will probably continue to remain the standard, low field systems offer advantages such as the feasibility of dynamic joint examinations, improvement of T1 contrast, reduction of “missile effects”, and decreased radiofrequency exposure. Low field strength MRI consequently has the potential to contribute to optimal patient management and, given comparable image quality, its application may become an issue of patient safety. This book will be an invaluable asset to all who are involved in planning and/or running a low field strength MRI facility.
650
0
$a
Radiology.
$3
673943
650
0
$a
Surgery.
$3
644132
650
0
$a
Neurology .
$3
1253459
650
1 4
$a
Diagnostic Radiology.
$3
593950
650
2 4
$a
Neurology.
$3
593894
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer Nature eBook
776
0 8
$i
Printed edition:
$z
9783319165158
776
0 8
$i
Printed edition:
$z
9783319165172
776
0 8
$i
Printed edition:
$z
9783319365084
856
4 0
$u
https://doi.org/10.1007/978-3-319-16516-5
912
$a
ZDB-2-SME
912
$a
ZDB-2-SXM
950
$a
Medicine (SpringerNature-11650)
950
$a
Medicine (R0) (SpringerNature-43714)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入