語系:
繁體中文
English
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Collimator-Based Tracking with an Ad...
~
Böhler, Andreas.
Collimator-Based Tracking with an Add-On Multileaf Collimator = Modification of a commercial collimator system for realtime applications /
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Collimator-Based Tracking with an Add-On Multileaf Collimator/ by Andreas Böhler.
其他題名:
Modification of a commercial collimator system for realtime applications /
作者:
Böhler, Andreas.
面頁冊數:
XIV, 53 p. 18 illus., 14 illus. in color.online resource. :
Contained By:
Springer Nature eBook
標題:
Radiotherapy. -
電子資源:
https://doi.org/10.1007/978-3-658-10658-4
ISBN:
9783658106584
Collimator-Based Tracking with an Add-On Multileaf Collimator = Modification of a commercial collimator system for realtime applications /
Böhler, Andreas.
Collimator-Based Tracking with an Add-On Multileaf Collimator
Modification of a commercial collimator system for realtime applications /[electronic resource] :by Andreas Böhler. - 1st ed. 2016. - XIV, 53 p. 18 illus., 14 illus. in color.online resource. - BestMedDiss,2626-7659. - BestMedDiss,.
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical. Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it. Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets. Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
ISBN: 9783658106584
Standard No.: 10.1007/978-3-658-10658-4doiSubjects--Topical Terms:
593952
Radiotherapy.
LC Class. No.: RM845-862.5
Dewey Class. No.: 615.842
Collimator-Based Tracking with an Add-On Multileaf Collimator = Modification of a commercial collimator system for realtime applications /
LDR
:02808nam a22003975i 4500
001
980654
003
DE-He213
005
20200629140046.0
007
cr nn 008mamaa
008
201211s2016 gw | s |||| 0|eng d
020
$a
9783658106584
$9
978-3-658-10658-4
024
7
$a
10.1007/978-3-658-10658-4
$2
doi
035
$a
978-3-658-10658-4
050
4
$a
RM845-862.5
072
7
$a
MJCL1
$2
bicssc
072
7
$a
MED080000
$2
bisacsh
072
7
$a
MJCL1
$2
thema
082
0 4
$a
615.842
$2
23
100
1
$a
Böhler, Andreas.
$e
author.
$4
aut
$4
http://id.loc.gov/vocabulary/relators/aut
$3
1273343
245
1 0
$a
Collimator-Based Tracking with an Add-On Multileaf Collimator
$h
[electronic resource] :
$b
Modification of a commercial collimator system for realtime applications /
$c
by Andreas Böhler.
250
$a
1st ed. 2016.
264
1
$a
Wiesbaden :
$b
Springer Fachmedien Wiesbaden :
$b
Imprint: Springer,
$c
2016.
300
$a
XIV, 53 p. 18 illus., 14 illus. in color.
$b
online resource.
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
347
$a
text file
$b
PDF
$2
rda
490
1
$a
BestMedDiss,
$x
2626-7659
505
0
$a
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
520
$a
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical. Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it. Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets. Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
650
0
$a
Radiotherapy.
$3
593952
650
0
$a
Oncology .
$3
1253469
650
2 4
$a
Oncology.
$3
593951
710
2
$a
SpringerLink (Online service)
$3
593884
773
0
$t
Springer Nature eBook
776
0 8
$i
Printed edition:
$z
9783658106577
776
0 8
$i
Printed edition:
$z
9783658106591
830
0
$a
BestMedDiss,
$x
2626-7659
$3
1258473
856
4 0
$u
https://doi.org/10.1007/978-3-658-10658-4
912
$a
ZDB-2-SME
912
$a
ZDB-2-SXM
950
$a
Medicine (SpringerNature-11650)
950
$a
Medicine (R0) (SpringerNature-43714)
筆 0 讀者評論
多媒體
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼[密碼必須為2種組合(英文和數字)及長度為10碼以上]
登入