Language:
English
繁體中文
Help
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Utilizing ASHRAE G36 for Free Outsid...
~
Rodriguez, Alejandro.
Utilizing ASHRAE G36 for Free Outside Air Cooling (Economizer).
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Utilizing ASHRAE G36 for Free Outside Air Cooling (Economizer)./
Author:
Rodriguez, Alejandro.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
Description:
121 p.
Notes:
Source: Dissertations Abstracts International, Volume: 80-06, Section: B.
Contained By:
Dissertations Abstracts International80-06B.
Subject:
Mechanical engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13420270
ISBN:
9780438711983
Utilizing ASHRAE G36 for Free Outside Air Cooling (Economizer).
Rodriguez, Alejandro.
Utilizing ASHRAE G36 for Free Outside Air Cooling (Economizer).
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 121 p.
Source: Dissertations Abstracts International, Volume: 80-06, Section: B.
Thesis (D.Engr.)--The George Washington University, 2019.
This item must not be sold to any third party vendors.
Until 2018, there were no guidelines for the sequencing of operations in common heating, ventilation, and air conditioning (HVAC) systems. In that year, American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) published Guideline 36, which provides a uniform set of control sequences that improves energy efficiency in buildings. All mechanical engineers may base their HVAC designs on this guideline. Before ASHRAE Guideline 36, HVAC engineers created their own designs independently. Commissioning agents followed through with custom commissioning strategies to meet the design specified by the HVAC designers. In addition, the typical construction project delivery methods did not facilitate communication between the design teams and building contractors. The intent of this praxis is to determine whether Guideline 36 energy savings have in fact been realized by the building owners and offer a framework/approach for building owners to assess whether their systems economizer cycles are functioning per the guideline. This study examines Air Handling Unit (AHU) operational data before and after the adoption of ASHRAE G36 to determine whether implementing the guidelines actually helped to reduce the AHU mechanical cooling loads. This praxis will produce an ASHRAE G36 adoption timeline that building owners may follow to implement the guidelines in both new and existing buildings. A Guideline 36 validating framework will also be proposed so that building owners may confirm their AHUs’ adherence to the guideline.
ISBN: 9780438711983Subjects--Topical Terms:
557493
Mechanical engineering.
Subjects--Index Terms:
Control sequences
Utilizing ASHRAE G36 for Free Outside Air Cooling (Economizer).
LDR
:02716nam a2200361 4500
001
951772
005
20200821052152.5
008
200914s2019 ||||||||||||||||| ||eng d
020
$a
9780438711983
035
$a
(MiAaPQ)AAI13420270
035
$a
(MiAaPQ)gwu:14495
035
$a
AAI13420270
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Rodriguez, Alejandro.
$3
1241238
245
1 0
$a
Utilizing ASHRAE G36 for Free Outside Air Cooling (Economizer).
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
121 p.
500
$a
Source: Dissertations Abstracts International, Volume: 80-06, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Blackburn, Timothy.
502
$a
Thesis (D.Engr.)--The George Washington University, 2019.
506
$a
This item must not be sold to any third party vendors.
520
$a
Until 2018, there were no guidelines for the sequencing of operations in common heating, ventilation, and air conditioning (HVAC) systems. In that year, American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) published Guideline 36, which provides a uniform set of control sequences that improves energy efficiency in buildings. All mechanical engineers may base their HVAC designs on this guideline. Before ASHRAE Guideline 36, HVAC engineers created their own designs independently. Commissioning agents followed through with custom commissioning strategies to meet the design specified by the HVAC designers. In addition, the typical construction project delivery methods did not facilitate communication between the design teams and building contractors. The intent of this praxis is to determine whether Guideline 36 energy savings have in fact been realized by the building owners and offer a framework/approach for building owners to assess whether their systems economizer cycles are functioning per the guideline. This study examines Air Handling Unit (AHU) operational data before and after the adoption of ASHRAE G36 to determine whether implementing the guidelines actually helped to reduce the AHU mechanical cooling loads. This praxis will produce an ASHRAE G36 adoption timeline that building owners may follow to implement the guidelines in both new and existing buildings. A Guideline 36 validating framework will also be proposed so that building owners may confirm their AHUs’ adherence to the guideline.
590
$a
School code: 0075.
650
4
$a
Mechanical engineering.
$3
557493
650
4
$a
Energy.
$3
784773
653
$a
Control sequences
653
$a
Energy savings
653
$a
HVAC systems
690
$a
0548
690
$a
0791
710
2
$a
The George Washington University.
$b
Engineering Management.
$3
1179162
773
0
$t
Dissertations Abstracts International
$g
80-06B.
790
$a
0075
791
$a
D.Engr.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13420270
based on 0 review(s)
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login